搜索热: 蒸发器
扫一扫 加微信
首页 > 期刊论文 > 论文摘要
基于Barker码的一发两收超声TOFD技术在检测倾斜裂纹中的应用
          
Application of Ultrasoinc TOFD Technology with One Transmitter and Two Receivers Based on Barker Code in Detecting Inclined Cracks

摘    要
在传统超声TOFD技术的基础上,将Barker码激励与一发两收TOFD技术结合起来,根据两个接收探头接收声波的声程差,准确定位裂纹的两个端点,进而定量地检测倾斜裂纹。有限元仿真结果表明,基于Barker码匹配压缩后的衍射回波信号的精度可达到0.01 μs,检测倾斜裂纹角度的平均误差为1.62°。
标    签 无损检测   超声衍射时差法   倾斜裂纹   巴克码激励   NDT   TOFD   inclined crack   barker code excitation  
 
Abstract
This paper combined the Barker code excitation with the modified TOFD with double receivers on the basis of traditional TOFD technique. Based on the travelling times received by the two receivers, the positions of two crack tips were acquired to quantitatively evaluate inclined cracks. FEM simulation results showed that the time resolution of the signal compressed by Barker code excitation could be up to 0.01 μs and the average error of the estimated orientation was 1.62°.

中图分类号 TG115.28   DOI 10.11973/wsjc201712009

 
  购买该论文  中国光学期刊网论文下载说明


所属栏目 试验研究

基金项目 国家自然科学基金资助项目(11574072,11274091);江苏省重点研发计划项目(BE2016056)

收稿日期 2017/5/15

修改稿日期

网络出版日期

作者单位点击查看


备注王鹏(1993-),男,硕士,研究方向为通信与信息系统

引用该论文: WANG Peng,HAN Qingbang,JIANG Xueping,ZHENG Hao,XU Zhouchen. Application of Ultrasoinc TOFD Technology with One Transmitter and Two Receivers Based on Barker Code in Detecting Inclined Cracks[J]. Nondestructive Testing, 2017, 39(12): 40~43
王鹏,韩庆邦,姜学平,郑豪,许洲琛. 基于Barker码的一发两收超声TOFD技术在检测倾斜裂纹中的应用[J]. 无损检测, 2017, 39(12): 40~43


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】SILK M G. The transfer of ultrasonic energy in the diffraction technique for crack sizing[J]. Ultrasonics, 1979, 17(3):113-121.
 
【2】SILK M G. Changes in ultrasonic defect location and sizing[J]. NDT International, 1987, 20(1):9-14.
 
【3】CIORAU P. Critical comments on detection and sizing linear defects by conventional tip-echo diffraction and mode-converted ultrasonic techniques for piping and pressure vessel welds[J]. NDT. The E-Journal of Nondestructive Testing, 2006,11(5):1-7.
 
【4】HOSEINI M R, WANG X, ZUO M J. Modified relative arrival time technique for sizing inclined cracks[J]. Measurement, 2014, 50(50):86-92.
 
【5】陈婷婷. 基于超声TOFD-LWE检测方法的缺陷识别与研究[D]. 哈尔滨:哈尔滨工程大学, 2011.
 
【6】康达,张树潇,金士杰,等. 基于几何方法的焊缝倾斜裂纹TOFD定量检测[J].无损检测,2016, 38(4):1-5.
 
【7】ZHANG H, WU S, TA D, et al. Coded excitation of ultrasonic guided waves in long bone fracture assessment[J]. Ultrasonics, 2014, 54(5):1203-1209.
 
【8】DE M A, DE N S, HUANG Y, et al. Code design to optimize radar detection performance under accuracy and similarity constraints[J]. IEEE Transactions on Signal Processing, 2008, 56(11):5618-5629.
 
【9】周正干, 马保全, 孙志明,等. 相位编码脉冲压缩方法在空气耦合超声检测信号处理中的应用[J]. 机械工程学报, 2014, 50(2):48-54.
 
【10】丛森, 刚铁, 张佳莹,等. LFM激励信号在超声TOFD检测中的应用[J]. 焊接学报, 2015, 36(2):63-66.
 
【11】NOWICKI A, LITNIEWSKI J, SECOMSKI W, et al. Estimation of ultrasonic attenuation in a bone using coded excitation[J]. Ultrasonics, 2003, 41(8):615-621.
 
【12】宋小春, 王亚午, 涂君,等. 基于超声衍射时差法的缺陷检测技术仿真分析[J]. 传感器与微系统, 2015, 34(5):55-58.
 
【13】BABY S, BALASUBRAMANIAN T, PARDIKAR R J, et al. Time-of-flight diffraction (TOFD) technique for accurate sizing of surfae-breaking cracks[J]. Insight-Non-Destructive Testing and Condition Monitoring, 2003, 45(6):426-430.
 
相关信息
   标题 相关频次
 相控阵超声检测扇形扫描角度范围
 4
 相控阵超声检测声场近场区长度的理论
 4
 厚壁高强钢球罐埋藏裂纹的TOFD检测及其成因分析
 3
 基于几何方法的焊缝倾斜裂纹TOFD定量检测
 3
 2014'中国无损检测年度报告
 2
 2015'中国无损检测年度报告——实时记录中国NDT技术与行业发展进程
 2
 GQ80型铁路罐车的射线检测
 2
 P110钢级油管接箍开裂失效分析
 2
 P91钢管对接焊缝层间裂纹的超声波检测
 2
 QNDE的核心科学与工程基础进展
 2
 SiC颗粒增强铝基复合材料缺陷的无损检测
 2
 TOFD方法对焊接缺陷的检测能力
 2
 TOFD检测中扫查方式与检测盲区的关系
 2
 TOFD无损检测技术实操培训班
 2
 T型焊接接头的超声波TOFD检测方法
 2
 不同材料金属橡胶在中性盐液中的耐腐蚀及阻尼性能
 2
 超声衍射时差法用于核电站常规岛管道焊缝检测的可行性
 2
 磁巴克豪森噪声技术的发展现状
 2
 磁声发射检测技术研究进展
 2
 从两种检测方法的检验结果看无损检测工艺编制的重要性
 2
 大口径X70感应加热试制弯管的组织与性能
 2
 电感耦合等离子体质谱法测定核级海绵锆中钨
 2
 镀镍与镀铜对SiCp/6063Al复合材料真空钎焊接头剪切强度的影响
 2
 端点衍射法测量焊接接头内部缺陷高度
 2
 多向纤维缠绕玻璃钢管的轴向压缩性能
 2
 非平面工件对接焊缝TOFD检测工艺
 2
 风力发电设备无损检测技术研究
 2
 复合材料的现场电子剪切散斑检测技术研究
 2
 高体积分数SiCp增强6063Al基复合材料的真空加压钎焊
 2
 高压锅炉无缝钢管爆裂原因分析
 2