Application of an Anti-freezing Reference Electrode to Cathodic Protection System in Permafrost Evironment
摘 要
针对目前常用参比电极(高纯Zn及Cu/CuSO4参比电极)在低温环境中基准电位不稳定的现状,研制了一套可应用于冻土区阴极保护系统的的新型防冻型Cu/CuSO4参比电极。通过与常用参比电极在实验室及现场对比,该电极在低温下性能稳定,设计结构合理,使用方便。
Abstract
A new type of anti-freezing Cu/CuSO4 reference electrode was applied to cathodic protection system to overcome the problem that the common reference electrodes (purity Zn and Cu/CuSO4 reference electrode) failed to hold stable potentials in low-temperature environments. The experimental and field data showed that the anti-freezing reference electrode exhibited excellent advantages of stable potentials, reasonable structure, easy to use in low temperature environments in comparison with common reference electrodes.
中图分类号 TG174.41 TE988
所属栏目 应用技术
基金项目
收稿日期 2013/10/31
修改稿日期
网络出版日期
作者单位点击查看
备注徐承伟(1982-),工程师,博士,从事管道的腐蚀与防护工作,
引用该论文: XU Cheng-wei,LIU Xiao-peng,ZHAO Jian-tao,ZHENG Jun,HE Fei,TENG Yan-ping. Application of an Anti-freezing Reference Electrode to Cathodic Protection System in Permafrost Evironment[J]. Corrosion & Protection, 2014, 35(5): 505
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】薛致远,张丰,毕武喜,等. 北部管网阴极保护通/断电电位测量与分析[J]. 油气储运,2010,29(10): 772-773.
【2】胡士信. 阴极保护工程手册[M]. 北京: 化学工业出版社,1999.
【3】张玲玲,杜敏,颜民. 工程用参比电极的进展[J]. 腐蚀科学与防护技术,2006,103(6): 433-435.
【4】武晓峰. 季节性冻土条件下阴极保护参数测试技术[J]. 油气田地面工程,2010(8): 103-104.
【2】胡士信. 阴极保护工程手册[M]. 北京: 化学工业出版社,1999.
【3】张玲玲,杜敏,颜民. 工程用参比电极的进展[J]. 腐蚀科学与防护技术,2006,103(6): 433-435.
【4】武晓峰. 季节性冻土条件下阴极保护参数测试技术[J]. 油气田地面工程,2010(8): 103-104.
相关信息