System Compliance and Strain Rate Control of ISO 6892-1: 2009
摘 要
探讨了金属材料室温拉伸试验时系统柔度对试验结果的影响, 并结合对系统柔度的理解和认识, 分析了不同类型夹具依据ISO 6892-1:2009进行试验的使用情况, 给出了英斯特朗夹具系统符合ISO 6892-1: 2009应变控制的建议。最后介绍了英斯特朗的自适应闭环算法特点。
Abstract
The influence of system compliance on metallic material tensile testing results at room temperature was discussed. Combining with the understanding of system compliance, the usage condition of different types of grips according to ISO 6892-1:2009 was analyzed, and a proposal that the Instron’s grip system was in accordance with the strain control requirement of ISO 6892-1:2009 was given. Finally, the feature of Instron’s adaptive control algorithms was introduced.
中图分类号 TG115.5 TH871.1
所属栏目 专题报道
基金项目
收稿日期 2013/10/28
修改稿日期
网络出版日期
作者单位点击查看
备注DAVID Fry(1982-),男,硕士。
引用该论文: DAVID Fry. System Compliance and Strain Rate Control of ISO 6892-1: 2009[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2014, 50(4): 249~250
DAVID Fry. 系统柔度与ISO 6892-1:2009应变速率控制[J]. 理化检验-物理分册, 2014, 50(4): 249~250