Definition and Preservation on Original Digital Image in Digital Radiography
摘 要
在数字射线成像检测方法中,需要明确原始图像数据的含义,并对其进行有效的保存与归档。通过分析得出,数字射线成像中原始图像应是数字射线探测器校正后得到的最初图像;原始图像数据经图像处理后可获得更好的视觉效果,但应注意方法的正确使用,避免改写原始数据;利用数据库技术可实现数字化射线检测图像的有效管理和归档。
Abstract
Original digital image in digital radiography needs appropriate archiving, and the definition of original digital image need to be specified first. It indicates following the analysis that the: original digital image should be the raw image from digital detector after calibration; better visual effect can be achieved by image processing techniques on original image. The original data should not be overwritten by some improper processing and management and archiving of original digital image can be done effectively by using database method.
中图分类号 TG115.28
所属栏目 实践经验
基金项目
收稿日期 2013/4/12
修改稿日期
网络出版日期
作者单位点击查看
备注孙朝明(1977-),男,高工,主要从事无损检测工作。
引用该论文: SUN Chao-ming. Definition and Preservation on Original Digital Image in Digital Radiography[J]. Nondestructive Testing, 2014, 36(2): 56~59
孙朝明. 数字射线成像中原始图像数据的定义与保存[J]. 无损检测, 2014, 36(2): 56~59
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】Gary Barber, Digital imaging techniques/solutions[DB/OL], NDT.net.
【2】ASTM E 1411Standard practice for qualification of radioscopic systems[S].
【3】ASTM E2007Standard guide for computed radiography[S].
【4】Carter, Christi E. Digital radiography and pacs[M]. Missouri, USA: Mosby Elsevier,2010.
【5】ASTM E 2597Standard practice for manufacturing characterization of digital detector arrays[S].
【6】ISO/DIS 17636-2Non-destructive testing of welds — Radiographic testing —Part 2: X- and gamma-ray techniques with digital detectors[S].
【7】Andrea Koetz, Sue Clendening. The value of DICONDE[DB/OL], NDT.net.
【8】ASTM E 2339Standard practice for digital imaging and communication in nondestructive evaluation(DICONDE)[S].
【2】ASTM E 1411Standard practice for qualification of radioscopic systems[S].
【3】ASTM E2007Standard guide for computed radiography[S].
【4】Carter, Christi E. Digital radiography and pacs[M]. Missouri, USA: Mosby Elsevier,2010.
【5】ASTM E 2597Standard practice for manufacturing characterization of digital detector arrays[S].
【6】ISO/DIS 17636-2Non-destructive testing of welds — Radiographic testing —Part 2: X- and gamma-ray techniques with digital detectors[S].
【7】Andrea Koetz, Sue Clendening. The value of DICONDE[DB/OL], NDT.net.
【8】ASTM E 2339Standard practice for digital imaging and communication in nondestructive evaluation(DICONDE)[S].
相关信息