Pulsed Eddy Current Testing of Corrosion under Insulation in Pipes Based on Magnetic Field Sensor
摘 要
使用隧道磁电阻(TMR)传感器对带包覆层的铁磁性管道的腐蚀进行脉冲涡流检测时,地磁场会对检测结果有影响。管道东西向放置时,针对70 mm包覆层铁磁性管道腐蚀,TMR磁传感器分别放置于管道正上方、相对偏转45°、相对偏转90°进行了检测试验。试验结果表明,TMR放置角度对检测有一定影响;在实际检测中,TMR的接收方向与地磁场方向的角度发生较大改变时,应重新选取检测的参考基准。
Abstract
In this paper, TMR magnetic field sensor was used to detect corrosion under insulation in ferromagnetic pipes with pulsed eddy current testing. To improve detection accuracy, effect of geomagnetic field on testing was studied. A pipe with 70mm insulation was placed to the east-west and experiments were performed with TMR magnetic field sensor placed at different positions, over the pipe, the side of 45 degree from the top and the side of 90 degrees from the top respectively. The experimental results show that probe orientation has a significant influence on the detection . In actual testing, if receiving direction of TMR with respect to the geomagnetic field is changed greatly, reference standard should be reselected.
中图分类号 TG115.28
所属栏目 试验研究
基金项目 国家自然科学基金资助项目(51067007);江西省自然科学基金资助项目(2007GZW1530)
收稿日期 2013/8/19
修改稿日期
网络出版日期
作者单位点击查看
备注严超操(1988-),男,硕士研究生,主要从事电磁无损检测的研究。
引用该论文: YAN Chao-cao,FU Yue-wen,WEI Dao-xiang. Pulsed Eddy Current Testing of Corrosion under Insulation in Pipes Based on Magnetic Field Sensor[J]. Nondestructive Testing, 2014, 36(3): 21~24
严超操,付跃文,蔚道祥. 基于磁传感器的带包覆层管道腐蚀脉冲涡流检测[J]. 无损检测, 2014, 36(3): 21~24
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】郑中兴,韩志刚.穿透保温层和防腐层的脉冲涡流检测壁厚检测[J].无损探伤,2008,32(1):1-4.
【2】张斌强.脉冲涡流检测系统的设计与研究[D].南京:南京航空航天大学,2009.
【3】何赟泽.脉冲涡流无损检测技术研究[D].长沙:国防科学技术大学,2008.
【4】吕华.隧道磁电阻(TMR)磁传感器的特性与应用[J].磁性材料及仪器,2012,43(3):1-4.
【5】康小伟,付跃文.带包覆层铁磁性管道腐蚀脉冲涡流检测技术[J].无损检测,2011,33(9):40-42.
【2】张斌强.脉冲涡流检测系统的设计与研究[D].南京:南京航空航天大学,2009.
【3】何赟泽.脉冲涡流无损检测技术研究[D].长沙:国防科学技术大学,2008.
【4】吕华.隧道磁电阻(TMR)磁传感器的特性与应用[J].磁性材料及仪器,2012,43(3):1-4.
【5】康小伟,付跃文.带包覆层铁磁性管道腐蚀脉冲涡流检测技术[J].无损检测,2011,33(9):40-42.
相关信息