The Effect of Probe K Value Deviation on Detection Result in UT Detection
摘 要
对标称K值为2的探头,检测缺陷已知的钢板对接焊缝,在仪器输入的K值距测量的实际K值间有不同偏差的情况下 ,分别得出缺陷测量结果,分析了K值偏差对缺陷定位定量相关参数的影响程度,对参加超声检测二级考试学员的疑问得出了确切的回答,K值测量时产生的正负0.04范围内的误差不影响最终成绩,可以作为考级人员K值测量的参考。
Abstract
Using nominal K value of 2 to detect the given flaw of steel plant butt weld, the location and quantity parameter of the flaw in the case of inputting different K value with deviations were acquired. How the K value deviation was to affect the detection result was analyzed and questions by the candidates were answered. Deviation of ±0.04 for the K value shall not affect the grade of students and it will be a reference to candidates only.
中图分类号 TG115.28,TB552
所属栏目 实践经验
基金项目
收稿日期 2013/7/24
修改稿日期
网络出版日期
作者单位点击查看
备注王健(1968- ),女,实验师,硕士研究生,主要从事无损检测技术方面研究工作。
引用该论文: PEI Ke-fei,WANG Jian,LI Wen,NIU Xin-qian. The Effect of Probe K Value Deviation on Detection Result in UT Detection[J]. Nondestructive Testing, 2014, 36(6): 65~66
裴科飞,王健,李文,牛鑫乾. 焊缝超声检测探头K值偏差对检测结果的影响[J]. 无损检测, 2014, 36(6): 65~66
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】辽宁省特种设备无损检测人员资格考核委员会.超声波检测[M].辽宁大学出版社,2007:162-188.