摘    要
对于任何检测工作, 检测图像质量设计也就是技术级别设计。检测图像质量设计, 是对于要求检验的缺陷确定检测图像质量应达到对比度和不清晰度。对比度可按射线检测技术建立的检测图像上缺陷显示与像质计显示关系完成, 不清晰度可按采样定理完成。给出了气孔缺陷检验技术级别设计的具体处理。
标    签 数字射线检测   技术级别   缺陷检验   射线检测   Digital radiography   Technical classification   Flaw inspection   Radiology  
 
Abstract
For any testing problem, the design of the testing technical classification is just the design of the testing image quality. The design of the testing image quality determines mainly the necessary achieve contrast and unsharpness of the image upon the expectant detective flaw. The contrast value can be designed on the established correlation in radiology between flaw imaging and IQI imaging. The unsharpness value must be designed on the sampling theorem. A practice designing procedure of testing technical classification was given for detection of gashole flaw.

中图分类号 TG115.28

 
  中国光学期刊网论文下载说明


所属栏目 数字射线检测技术专题

基金项目

收稿日期 2014/2/19

修改稿日期

网络出版日期

作者单位点击查看

备注郑世才(1941-), 男, 研究员, 长期从事常规射线, 超声, 磁粉和渗透检测工作, 重点研究射线检测技术的理论和发展。

引用该论文: ZHENG Shi-cai. Digital Radiography Ⅲ: The Approximate Design of the Testing Technical Classification[J]. Nondestructive Testing, 2014, 36(9): 5~7
郑世才. 数字射线检测技术专题(三)——技术级别近似设计[J]. 无损检测, 2014, 36(9): 5~7


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】E L CRISCUOLO. Correlation of radiographic penetrameters[J]. Materials Research & Standards,1963,3(6):465-471.
 
【2】(日)石井勇五郎.无损检测学[M].北京: 机械工业出版社, 1986.C G POLLITT. Radiographic sensitivity[J].Brit.J.NDT,1962,4(3):71-80.
 
【3】R HALMSHAW. Industrial Radiology: Theory and Practice[M]. New Jersey: Applied Science Publishers LTD, 1982.
 
【4】R HALMSHAW. Physics of Industrial radiology[M].New York, London Heywood Books American Elsevier Publishing Company Inc, 1966.
 
【5】ASTM E747-94 Design, manufacture and material grouping classification of wire image quality indicatiors(IQI)used for radiology.[S]
 
【6】BS 7257: 1989 Radiographic examination of fusion welded branch and nozzle joints in steel.[S]
 
【7】E L CRISCUOLO. Radiography and visual perception[J].Nondestructive Testing, 1962: 20(6):373-401.
 
【8】郑世才.数字射线无损检测技术[M].北京: 机械工业出版社, 2012.
 
相关信息
   标题 相关频次
 数字射线检测技术(五)——补偿规则说明
 6
 数字射线检测技术(五)——补偿规则说明
 6
 数字射线检测技术专题(一)——概述
 6
 数字射线检测技术(四)——等价技术级别评定
 5
 数字射线检测技术专题(二)——探测器系统选择
 5
 X射线机不是计量器具
 3
 对《射线检测小径管的灵敏度对比试验》一文的看法
 3
 数字射线检测技术(六)——数字射线检测技术标准介绍
 3
 数字射线检测技术专题(二)——辐射探测器介绍
 3
 数字射线检测技术专题(六)——等价性问题讨论
 3
 数字射线检测技术专题(三)——成像过程基本理论
 3
 数字射线检测技术专题(四)——数字射线图像基本理论
 3
 数字射线检测技术专题(五)——数字射线检测基本技术
 3
 DR技术几何不清晰度的控制
 2
 X射线管焦点尺寸的测量
 2
 X射线机焦点尺寸测量方法的标准分析
 2
 X射线数字透射成像图像质量影响因素分析
 2
 不清晰度的测量
 2
 对ASTM E1742—2008标准射线照相质量级别规定的讨论
 2
 关于X射线机的透照灵敏度
 2
 基于小波变换的双能DR图像融合
 2
 胶片射线检测与数字射线检测的焊接缺陷检出能力比较
 2
 可检验的最小气孔尺寸的确定方法
 2
 数字射线检测技术专题(一)——概述
 2
 数字射线透照技术的现状与发展
 2
 数字射线照相法现状评述
 2
 新型双丝像质计设计
 2
 一种基于检测技术级别的射线检测参数优化方法
 2
 最佳黑度的误导
 2
 (海量美图)你以为是水墨画?其实它是科学家的X光片!
 1