Application of Flexible Anode to Regional Cathodic Protection of Crude Oil Tank Farm
摘 要
采用AnodeFlex 1500-01柔性阳极的强制电流的保护方式, 是目前复杂站场区域阴极保护最可靠的保护方式。文章介绍了柔性阳极保护系统的组成及原理, 并以鄯善生产运行储备库为例, 详细介绍柔性阳极的施工要点及注意事项。本例可供复杂站场埋地管线阴极保护工程施工参考。
Abstract
The AnodeFlex 1500-01 flexible anode impressed current protection form is the most reliable protection in the complex area of cathodic protection stations. This article introduces the compostion and principle of the flexible anodic protection system, and takes Shanshan production-running crude oil tank farm as an example, introducs the key construction points and matters needing attention for flexible anodes. The example may provide construction reference to the buried pipelines with cathodic protection in complex station.
中图分类号 TG174.41
所属栏目 应用技术
基金项目
收稿日期 2011/3/12
修改稿日期
网络出版日期
作者单位点击查看
联系人作者徐公银(klmyxgy@163.com)
备注徐公银,工程师,
引用该论文: XU Gong-yin. Application of Flexible Anode to Regional Cathodic Protection of Crude Oil Tank Farm[J]. Corrosion & Protection, 2012, 33(1): 72
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】贝克曼 W V,施文科 W,普林茨 W. 阴极保护手册电化学保护的理论与实践[M]. 胡士信,王向农译. 北京:化学工业出版社,2005.