Measurement and Reduction of Stray Current on Buried Steel Pipeline
摘 要
随着机动轨车及电力网络的快速发展, 其引起的杂散电流给埋地钢质管道造成的快速腐蚀已严重危害管道安全。首先介绍了常见的杂散电流干扰源及其可能造成的严重危害, 接着介绍了杂散电流是否存在及干扰源定位的检测判断方法, 之后介绍了当前常用的杂散电流防护与排流方法, 最后以工程实例说明杂散电流的检测、判断方法和排流改造及效果整个过程。文章系统地从杂散电流的来源、判断、干扰源确定及排流和效果评定介绍了埋地钢质管道杂散电流防护工程的流程。
Abstract
Stray current caused by traction and power systems has caused serious corrosion risk to buried steel pipelines. This article describes sources and harmful effect of stray current, measurement ways to identify stray current and to locate stray current, reduction ways of stray current interference, and gives two examples to explain the whole process about identification, measurement and reduction of stray current on buried steel pipelines. The article can provide a reference for stray current control project.
中图分类号 TG174
所属栏目 应用技术
基金项目
收稿日期 2011/6/14
修改稿日期
网络出版日期
作者单位点击查看
联系人作者杨永(yystanb@163.com)
备注杨永, 工程师, 硕士,
引用该论文: YANG Yong,HE Ren-yang,LI Gang,HAN Yue-hong,LI Zi-sheng. Measurement and Reduction of Stray Current on Buried Steel Pipeline[J]. Corrosion & Protection, 2012, 33(4): 324
被引情况:
【1】范列朋,陈银, "庭院引入管上杂散电流的影响及应对措施",腐蚀与防护 34, 940-942(2013)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】胡士信. 阴极保护工程手册[M]. 北京: 化学工业出版社, 1999: 255-256.
【2】BS EN 50162-2004. Protection against corrosion by stray current from direct current systems[S].
【3】BS EN 12954-2001. Cathodic protection of buried or immersed metallic structures[S].
【4】SY/T 0032-2000. 埋地钢质管道交流排流保护技术标准[S].
【5】SY/T 0017-2006. 埋地钢质管道直流排流保护技术标准[S].
【6】GB/T19285-2003. 埋地钢质管道腐蚀防护工程[S].
【2】BS EN 50162-2004. Protection against corrosion by stray current from direct current systems[S].
【3】BS EN 12954-2001. Cathodic protection of buried or immersed metallic structures[S].
【4】SY/T 0032-2000. 埋地钢质管道交流排流保护技术标准[S].
【5】SY/T 0017-2006. 埋地钢质管道直流排流保护技术标准[S].
【6】GB/T19285-2003. 埋地钢质管道腐蚀防护工程[S].