Application and Corrosion of Duplex Steel in Coastal Power Plant
摘 要
介绍了双相不锈钢在某沿海电厂循环水泵上的应用, 指出循环水泵多次故障的原因是零部件之间存在缝隙腐蚀造成了紧固件松动;通过焊接消除间隙的措施来消除缝隙腐蚀, 介绍了常用的防护措施。实践表明虽然双相钢的抗腐蚀能力较其它常用材质较强, 但并不是绝对的, 在沿海电厂中的使用中应注重防护。
Abstract
This paper introduces the application of a duplex stainless steel used in circulating water pump in a coastal power plant, and points out that the cause of failure was the loose of fasteners caused by crevice corrosion between parts. By the processing of welding the crevice corrosion was eliminated. Some other protective measures are also proposed. The results show that the corrosion resistance of duplex steel is fairly strong, but not absolutely. When it is used in coastal power plant. it should be pay attention to the protection.
中图分类号 TG174
所属栏目 应用技术
基金项目
收稿日期 2011/8/24
修改稿日期
网络出版日期
作者单位点击查看
联系人作者王辉(258560588@qq.com)
备注王辉, 助理工程师, 本科,
引用该论文: WANG Hui. Application and Corrosion of Duplex Steel in Coastal Power Plant[J]. Corrosion & Protection, 2012, 33(7): 638
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】徐勇. 北仑电厂某机循泵轮毂腐蚀原因分析及处理[J]. 石油工程建设发电设备, 2004(2): 89-91.
【2】闫林娜, 尹衍升, 常雪婷, 等. 304不锈钢在微生物介质中的腐蚀行为[J]. 中国腐蚀与防护学报, 2008, 28(1): 34-37.
【3】陈强, 詹田友, 陈伟. 湛江发电厂循环水泵的腐蚀防护综合治理[J]. 广东电力, 2003, 30(8): 66-68.
【4】郑纪勇. 海洋生物污损与材料腐蚀[J]. 中国腐蚀与防护学报, 2010, 30(2):171-176.
【2】闫林娜, 尹衍升, 常雪婷, 等. 304不锈钢在微生物介质中的腐蚀行为[J]. 中国腐蚀与防护学报, 2008, 28(1): 34-37.
【3】陈强, 詹田友, 陈伟. 湛江发电厂循环水泵的腐蚀防护综合治理[J]. 广东电力, 2003, 30(8): 66-68.
【4】郑纪勇. 海洋生物污损与材料腐蚀[J]. 中国腐蚀与防护学报, 2010, 30(2):171-176.