陕京三线输气管道工程对受交流干扰的区段采用了集中接地、故障屏蔽、固态去耦合器接地等交流干扰防护新技术, 通过现场干扰程度调查与测试、防护效果检测评价、固态去耦合器运行参数、持续干扰防护接地点优化调整与测试等工作, 获得了详细的实际数据, 对固态去耦合器接地方式新技术的应用情况, 以及防护点的优化等进行了总结, 为埋地钢管交流干扰防护工程的设计、施工及运行测试提供参考。
Abstract
New technologies such as lumped ground , fault shield and solid-state DC decoupler grounding were used to protections against AC influence in Shanxi-Beijing Gas Pipeline Ⅲ. The application of solid-state DC decoupler grounding and the optimization of protection point were summarized. Based on the detailed data from the on-site tests of influence degree, inspections of protection effects, analyses of operation parameters of solid-state DC decoupler and optimization of grounding point the solid-state DC decoupler technology were summarized, which may provide a reference to the design, construction, operation and inspection of protection against AC influence for underground steel pipelines.
中图分类号 TG174.41 TE988
所属栏目 应用技术
基金项目
收稿日期 2011/9/20
修改稿日期
网络出版日期
作者单位点击查看
备注张平, 高级工程师, 学士,
引用该论文: ZHANG Ping,TONG Kai-ping,TU Hai-bo,CHENG Ming. New Technology Application and Optimization of AC Influence Mitigation for Shanxi-Beijing Gas Pipeline Ⅲ[J]. Corrosion & Protection, 2012, 33(8): 724
被引情况:
【1】韩非, "固态去耦合器与钳位式排流器的排流效果对比",腐蚀与防护 36, 1186-1189(2015)
【2】高安东, "固态去耦合器交流干扰缓解效果检测",腐蚀与防护 34, 95-97(2013)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】AS/NZS 4853: 2000. 澳大利亚/新西兰标准《金属管道上的电危害》[S].
【2】NACE SP0177-2007. 减轻交流电和雷电对金属构筑物和腐蚀控制系统影响的措施[S].
【3】Dabkowski J. Methodlogies for AC mitigation[C]//Corrosion 2003, Paper No.03703, Houston TX:NACE Int, 2003.
【4】ISO 15589-1: 2003. 管道输送系统的阴极保护(第一部分: 陆上管道)[S].
【2】NACE SP0177-2007. 减轻交流电和雷电对金属构筑物和腐蚀控制系统影响的措施[S].
【3】Dabkowski J. Methodlogies for AC mitigation[C]//Corrosion 2003, Paper No.03703, Houston TX:NACE Int, 2003.
【4】ISO 15589-1: 2003. 管道输送系统的阴极保护(第一部分: 陆上管道)[S].