Effect of Low Concentration Nitrite on Corrosion of A106B Carbon Steel
摘 要
为验证某电站闭式循环冷却水系统中的Fe2+含量显著增加是否由低浓度的污染离子NO2-引起, 采用静态挂片失重法、旋转挂片失重法和电化学方法评估了低浓度亚硝酸盐对碳钢材料的腐蚀影响。结果表明, 室温条件下, 在pH为10.0左右的除氧LiOH溶液中, 添加3 mg·kg-1 NaNO2使A106B碳钢的平均腐蚀速率从0.66 μm·a-1增大至0.99 μm·a-1, 但当空气漏入时A106B碳钢的平均腐蚀速率为73 μm·a-1。对比空气溶解引起水样碳酸化对腐蚀的影响, 低浓度NO2-的影响基本可以忽略。
Abstract
In order to test and verify whether the significantly increased iron concentration in a plant closed cooling water system was caused by the low concentration contamination of nitrite ion, the effect of nitrite on corrosion rate of A106B carbon steel was investigated by static weight loss, dynamic weight loss and electrochemical measurements. The results show that the corrosion rate of A106B steel was increased from 0.66 μm·a-1 to 0.99 μm·a-1 in the deaerated LiOH solution with pH value of 10.0 at a dosage of 3 mg·kg-1 NaNO2, however, the corrosion rate significantly increased to 73 μm·a-1 in the case of air inleakage because of the carbonation. As compared with the effect of dissolved oxygen and carbon dioxide, the effect of low concentration nitrite on the corrosion of carbon steel could be ignored.
中图分类号 TB304
所属栏目 试验研究
基金项目
收稿日期 2012/6/9
修改稿日期
网络出版日期
作者单位点击查看
备注刘斌, 工程师, 硕士,
引用该论文: LIU Bin,JIN Kai-feng,XIE Jian-li,LIU Tao,LU Jun-dong. Effect of Low Concentration Nitrite on Corrosion of A106B Carbon Steel[J]. Corrosion & Protection, 2013, 34(3): 228
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】刘旭麟, 彭乔, 刘顺华, 等.成膜剂对黑色金属防锈水防锈性能的影响[J].腐蚀与防护, 2010, 31(12):970-972.
【2】周本省.工业水处理技术[M].北京:化学工业出版社, 1997.
【3】郭稚弧.缓蚀剂及其应用[M] . 武汉:华中工学院出版社, 1987.
【4】朱元良, 赵艳娜, 刘斌.乙醇冷媒液中复配缓蚀剂的研究[J].腐蚀科学与防护技术, 2006, 18(4):296-299.
【5】GB/T 24196-2009 金属和合金的腐蚀 电化学试验方法[S].
【6】GB 50050-2007 工业循环冷却水处理设计规范[S].
【2】周本省.工业水处理技术[M].北京:化学工业出版社, 1997.
【3】郭稚弧.缓蚀剂及其应用[M] . 武汉:华中工学院出版社, 1987.
【4】朱元良, 赵艳娜, 刘斌.乙醇冷媒液中复配缓蚀剂的研究[J].腐蚀科学与防护技术, 2006, 18(4):296-299.
【5】GB/T 24196-2009 金属和合金的腐蚀 电化学试验方法[S].
【6】GB 50050-2007 工业循环冷却水处理设计规范[S].