Effect of Stray Current on Corrosion of X70 Pipeline Steel
摘 要
模拟现场杂散电流的干扰环境, 研究了杂散电流密度对管线钢腐蚀速率的影响规律。同时对比研究了交流、直流及交直流混流腐蚀的特点、影响规律及腐蚀机理。结果表明, 腐蚀速率随着杂散电流密度的增加而增大, 交直流在作用机理和腐蚀形式上存在差异, 研究结果为现场埋地管道杂散电流评价及研究提供借鉴。
Abstract
Using a simulation device, the influence of stray current density on corrosion rates of X70 pipeline steel was studied. A comparison investigation of AC, DC and (AC+DC) corrosion was carried out by simulated experiments. The stray current corrosion features and mechanism were analyzed. The results showed that the corrosion rate of X70 steel increased with the increase of stray current density.
中图分类号 TG174.3
所属栏目 试验研究
基金项目 中央高校基本科研业务费专项资金(11CX06077A); 中国石油大学(华东)研究生创新工程(CX-1240)
收稿日期 2012/5/7
修改稿日期
网络出版日期
作者单位点击查看
备注李自力, 教授,博士, 博士生导师,
引用该论文: YANG Yan,LI Zi-li,WEN Chuang. Effect of Stray Current on Corrosion of X70 Pipeline Steel[J]. Corrosion & Protection, 2013, 34(5): 391
被引情况:
【1】杨超,张成斌,李自力,赵雅蕾,崔淦,丁小勇, "直流杂散电流对X65钢腐蚀行为的影响",腐蚀与防护 37, 873-875(2016)
【2】叶远锡,李明,王勇, "输油管道杂散电流干扰的检测及对应措施",腐蚀与防护 37, 360-363(2016)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】Brian Martin. A history of stray current corrosion[J].Corrosion & Materials,2006,31(3):12-14.
【2】李自力, 孙云峰, 陈绍凯, 等.交流电气化铁路杂散电流对埋地管道电位影响规律[J].腐蚀与防护,2011,32(3) :177-181.
【3】董华清, 王亚平, 王家庆, 等.钟市-荆门输油管道杂散电流干扰测试与排除[J].腐蚀与防护,2008,29(11):698-670.
【4】苏俊华, 高立群, 冯仲文, 等.埋地钢质管道交流干扰及排流研究[J].腐蚀与防护,2011,32(7):551-557.
【5】王新华, 刘菊银, 何仁洋, 等.轨道交通动态杂散电流对埋地管道的干扰腐蚀试验[J].腐蚀与防护, 2010,31(3):193-197.
【6】郑敏聪.杂散电流对变电站接地网材料耐蚀性的影响[J].腐蚀与防护,2010,31(4):294-296.
【7】Bertocci U. AC induced corrosion. The effect of an alternating voltage on electrrodes under charge-transfer control[J].Corrosion, 1979, 35(5): 211-215.
【8】Goidanich S, Lazzari L, Ormellese M. AC corrosion-Part 1: Effect on overpotentials of anodic and cathodic processes[J]. Corrosion Science, 2009,51(2):491-497.
【9】Fu A Q, Cheng Y F. Effects of alternating current on corrosion of a coated pipeline steel in a chloride-containing carbonate/bicarbonate solution[J]. Corrosion Science,2010,52(2): 612-619.
【2】李自力, 孙云峰, 陈绍凯, 等.交流电气化铁路杂散电流对埋地管道电位影响规律[J].腐蚀与防护,2011,32(3) :177-181.
【3】董华清, 王亚平, 王家庆, 等.钟市-荆门输油管道杂散电流干扰测试与排除[J].腐蚀与防护,2008,29(11):698-670.
【4】苏俊华, 高立群, 冯仲文, 等.埋地钢质管道交流干扰及排流研究[J].腐蚀与防护,2011,32(7):551-557.
【5】王新华, 刘菊银, 何仁洋, 等.轨道交通动态杂散电流对埋地管道的干扰腐蚀试验[J].腐蚀与防护, 2010,31(3):193-197.
【6】郑敏聪.杂散电流对变电站接地网材料耐蚀性的影响[J].腐蚀与防护,2010,31(4):294-296.
【7】Bertocci U. AC induced corrosion. The effect of an alternating voltage on electrrodes under charge-transfer control[J].Corrosion, 1979, 35(5): 211-215.
【8】Goidanich S, Lazzari L, Ormellese M. AC corrosion-Part 1: Effect on overpotentials of anodic and cathodic processes[J]. Corrosion Science, 2009,51(2):491-497.
【9】Fu A Q, Cheng Y F. Effects of alternating current on corrosion of a coated pipeline steel in a chloride-containing carbonate/bicarbonate solution[J]. Corrosion Science,2010,52(2): 612-619.
相关信息