Layout Optimization of Cathodic Protection System of Natural Gas Gathering Pipeline
摘 要
埋地的天然气输送管道由于穿越各种类型的土壤、河流、湖泊, 腐蚀成为其安全运行的最大隐患。鄂尔多斯某天然气集输管网阴极保护系统是随着气田的发展逐年建设的, 采用防腐蚀涂料和强制电流阴极保护的技术对管线进行保护。为了对系统的运行现状进行评价和完善优化, 以现运行数据为基础, 利用ANSYS 软件建立了符合现状的模型; 利用该模型提出了阴极保护的优化方案, 并对其进行评估, 模拟结果显示管线保护效果良好。
Abstract
Buried gas pipeline may suffer corrosion because they may pass through various types of soil, rivers and lakes. Corrosion is the biggest hidden danger for safe operation of buried pipelines. A gas gathering pipeline system in Ordos is protected by anti-corrosion coatings and impressed current cathodic protection technology. To evaluate and optimize the operation status of the system, a model conforming to the present situation was established by using ANSYS software based on the running data. Cathodic protection optimization scheme was proposed by using the model, and then it was evaluated. The results show that the protection effect is good.
中图分类号 TG174.41 TE832
所属栏目 应用技术
基金项目
收稿日期 2013/3/29
修改稿日期
网络出版日期
作者单位点击查看
备注李稳宏,教授,博士生导师,
引用该论文: LEI Bao-gang,FAN Zheng,QIAO Yu-long,ZHU Yong-hong,LI Zhen-long,PAN Liu-yi,LI Wen-hong. Layout Optimization of Cathodic Protection System of Natural Gas Gathering Pipeline[J]. Corrosion & Protection, 2013, 34(7): 613
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】肖雯雯. 浅析油田集输管线的腐蚀原因及防腐措施[J]. 油气冶炼,2013,39(1):1-3.
【2】李月娥,袁鹏斌,颜达峰,等. 埋地钢质天然气管道失效分析[J]. 全面腐蚀控制,2013,27(1):49-53.
【3】王新华,陈文斌,何仁洋,等. 强制电流阴极保护管线系统的ANSYS仿真技术研究[J]. 腐蚀与防护,2008,29(增刊):107-112.
【2】李月娥,袁鹏斌,颜达峰,等. 埋地钢质天然气管道失效分析[J]. 全面腐蚀控制,2013,27(1):49-53.
【3】王新华,陈文斌,何仁洋,等. 强制电流阴极保护管线系统的ANSYS仿真技术研究[J]. 腐蚀与防护,2008,29(增刊):107-112.