Abnormal Reasons of Cathodic Protection System of a Debris Filter
摘 要
国内某电站机组首轮大修期间发现一个有牺牲阳极阴极保护的碎石过滤器表面大面积出现锈蚀。对阴极保护系统进行检查, 发现导致这一问题的原因是阳极与碎石过滤器、筒体与碎石过滤器之间都没有很好地连接, 导致阴极保护系统失效。提出了安装固定连接导电片、系统检修后重新测量点连接性改进措施。
Abstract
Corrosion was found on the out surface of a debris filter which was protected by an sacrificial anode cathodic protection system in a nuclear power plant in China. After checking the whole system, it is found that the poor connections between the anode and the filter as well as the cylinder and the filter were the main reasons causing the failure of cathodic protection. Improvement measures, such as adding extra conductive pieces and measuring the conductivity after system overhaul were proposed.
中图分类号 TG174.41
所属栏目 应用技术
基金项目
收稿日期 2012/8/27
修改稿日期
网络出版日期
作者单位点击查看
备注费克勋,工程师,硕士,
引用该论文: FEI Ke-xun,LIU Xiao-jun. Abnormal Reasons of Cathodic Protection System of a Debris Filter[J]. Corrosion & Protection, 2013, 34(7): 632