Macro and Micro Characteristics of Wire Melted Marks in Electrical Fire
摘 要
通过分析导线在火灾中形成熔痕的过程, 归纳了火烧熔痕、短路熔痕和过负荷熔痕的宏、微观特征, 据此可分析电气火灾事故的成因, 提出了用金相分析并结合现场勘查的方法来正确鉴定火灾的原因。
Abstract
Through forming process analysis of wire melted marks in the fire, the macro and micro characteristics of fire melted marks, short circuit and overload melted marks were concluded, which could be used to analyse the causes of electrical fire accidents. Metallographic analysis combining with on-site inspection was put forward to accurately indentify the causes of fire.
中图分类号 TG113
所属栏目 失效分析
基金项目 山东省科学院青年科学基金资助项目;科基合字(2011)第4号]
收稿日期 2012/9/3
修改稿日期 2013/6/10
网络出版日期
作者单位点击查看
备注徐娜(1979-), 女, 山东诸城人, 实验师, 硕士。
引用该论文: XU Na,LI En-xia,SHI Jun-bo,LI Yong-de,GUO Wei-min,YAN Guo-gang. Macro and Micro Characteristics of Wire Melted Marks in Electrical Fire[J]. Materials for mechancial engineering, 2013, 37(9): 103~106
徐娜,李恩霞,时军波,李永德,郭卫民,颜国刚. 电气火灾中导线熔痕的宏微观特征[J]. 机械工程材料, 2013, 37(9): 103~106
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】蒋清.浅谈电气线路的短路起火和线路过载[J].广东土木与建筑, 2004(4): 63-64.
【2】赵长征.电气火灾原因认定和痕迹鉴定[J].消防技术与产品信息, 2003(12): 3-5.
【3】杨晓红, 马子宁, 赵辉.电气火灾中导线熔痕的成因及形态特征的研究[J].东北电力技术, 2006(5): 15-19.
【4】王学峰.浅谈导线短路熔痕的鉴别[J].消防技术与产品信息, 2008(10): 57-58.
【5】GB/T 16840.1-2008电气火灾痕迹物证技术鉴定方法 第1部分: 宏观法;S].
【6】张学楷.线路过载电气火灾危险性的分析、预防要求及原因认定[J].消防技术与产品信息, 2008(11): 57-60.
【7】叶诗茂, 王立芬, 阳世群, 等.电气火灾中铜导线火烧痕的研究[J].理化检验-物理分册, 2007, 43(5): 226-231.
【2】赵长征.电气火灾原因认定和痕迹鉴定[J].消防技术与产品信息, 2003(12): 3-5.
【3】杨晓红, 马子宁, 赵辉.电气火灾中导线熔痕的成因及形态特征的研究[J].东北电力技术, 2006(5): 15-19.
【4】王学峰.浅谈导线短路熔痕的鉴别[J].消防技术与产品信息, 2008(10): 57-58.
【5】GB/T 16840.1-2008电气火灾痕迹物证技术鉴定方法 第1部分: 宏观法;S].
【6】张学楷.线路过载电气火灾危险性的分析、预防要求及原因认定[J].消防技术与产品信息, 2008(11): 57-60.
【7】叶诗茂, 王立芬, 阳世群, 等.电气火灾中铜导线火烧痕的研究[J].理化检验-物理分册, 2007, 43(5): 226-231.
相关信息