Determination of Si, Mn and P in Pig Iron by Direct-Reading Spectrography
摘 要
提出了采用HK 200型磨样机制样,直读光谱法测定生铁中硅、锰和磷的含量。探讨了基体效应、狭缝位置、分析条件和制样方法等影响因素。在优化的试验条件下,3种元素的相对标准偏差(n=11)均小于5%。方法用于生铁试样分析,测定结果与X射线荧光光谱法和分光光度法的测定结果基本一致。
Abstract
The sample was prepared with HK 200 sample grinder, and contents of Si, Mn and P in the sample were determined by the direct-reading spectrometer. Influential factors, including matrix effect, position of slit, analytical conditions and method of sample preparation were discussed. Under the optimized experimental condition, values of RSD′s (n=11) of the 3 elements found were less than 5%. The proposed method was applied to analysis of sample of pig iron, and the results obtained were in conformity with those by XRFS and spectrophotometry.
中图分类号 O657.3
所属栏目
基金项目
收稿日期 2009/12/6
修改稿日期
网络出版日期
作者单位点击查看
备注谢小运(1981-),男,湖南祁东人,研究方向为分析化学。
引用该论文: XIE Xiao-yun,LIU Yue-jin. Determination of Si, Mn and P in Pig Iron by Direct-Reading Spectrography[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2011, 47(1): 81~83
谢小运,刘跃进. 直读光谱法测定生铁中硅锰磷[J]. 理化检验-化学分册, 2011, 47(1): 81~83
被引情况:
【1】庞美玲,罗鲲翔,刘峰,张煜, "直读光谱法测定麻花钻中碳、硫、硅、锰、磷、铬、钒、钼和钨",理化检验-化学分册 48, 1233-1235(2012)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】陈必友,李启华.工厂分析化验手册[M].2版.北京:化学工业出版社, 2008.
【2】王孝杰,钟元康.锰磷硅自动分析仪在大型钢铁厂中的应用[J].理化检验-化学分册, 1995,31(6):347-347.
【3】朱纪厦,李庆美.X射线荧光光谱法快速测定生铁中硅锰硫磷钛[J].理化检验-化学分册, 2004,40(4):233-234.
【4】方红,杨晓兵,连庚宝,等.ICP-AES法测定生铁中硅锰磷的研究[J].理化检验-化学分册, 2001,37(3):127-128.
【2】王孝杰,钟元康.锰磷硅自动分析仪在大型钢铁厂中的应用[J].理化检验-化学分册, 1995,31(6):347-347.
【3】朱纪厦,李庆美.X射线荧光光谱法快速测定生铁中硅锰硫磷钛[J].理化检验-化学分册, 2004,40(4):233-234.
【4】方红,杨晓兵,连庚宝,等.ICP-AES法测定生铁中硅锰磷的研究[J].理化检验-化学分册, 2001,37(3):127-128.