Determination of Content of Nitrogen in ABS Resin by NIRS
摘 要
根据58个丙烯腈-丁二烯-苯乙烯(ABS)树脂样品的近红外漫反射光谱数据结合偏最小二乘法(PLS)建立了ABS树脂中氮含量定量分析的校正模型。结果表明:在近红外光谱区(7 501.8~5 449.9 cm-1)内,主因子数为9时,定量模型的准确度最好。通过对模型进行t-检验,在显著性水平为0.05的条件下,其测定结果与标准方法的测定结果对比,两者无显著性差异。预测相关系数(r)和相对标准偏差(RSD)分别为0.992 4和3.3%。
Abstract
Base on the spectral data of IR diffuse reflection of 58 samples of ABS resin (copolymer of acrylonitrile, butadiene and styrene) and on the application of calibration method of partial least square, a calibration model for determination of nitrogen in the resin was established. As shown by experimental results, highest accuracy was attained in the NIR spectral region of 7 501.8 to 5 449.9 cm-1 when taking 9 as the principal factor number. In the significance test of the model by t-test at the significance level of 0.05, no significant difference was found between the results found by the present method and the results found by the standard method. Values of predictive correlation coefficient (r) and relative standard deviation (RSD, n=7), found were 0.992 4 and 3.3% respectively.
中图分类号 O657.33
所属栏目
基金项目 国家质检总局科技计划资助项目(2008IK057)
收稿日期 2010/10/30
修改稿日期
网络出版日期
作者单位点击查看
备注杨文潮(1960-),男,舟山人,工程师,主要从事光谱与色谱分析。
引用该论文: YANG Wen-chao,WU Bei-lei,WANG Hao,LIN Zhen-xing. Determination of Content of Nitrogen in ABS Resin by NIRS[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2011, 47(3): 336~338
杨文潮,邬蓓蕾,王豪,林振兴. 近红外光谱法测定ABS树脂中氮含量[J]. 理化检验-化学分册, 2011, 47(3): 336~338
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】刘革,窦英,汤真.偏最小二乘法-近红外漫反射光谱法快速分析西米替丁粉末药品[J].生命科学仪器, 2004,2(6):33-35.
【2】严衍禄,赵龙莲.近红外光谱分析基础与应用[M].北京:中国轻工业出版社, 2005:87-89.
【3】DONALD A B, EMIL W C. Handbook of near-infrared analysis[M]. New York: Marcel Cekker Inc, 1992:93-94.
【4】郑用熙.分析化学中的数理统计方法[M].北京:中国农业出版社, 1986:106-122.
【2】严衍禄,赵龙莲.近红外光谱分析基础与应用[M].北京:中国轻工业出版社, 2005:87-89.
【3】DONALD A B, EMIL W C. Handbook of near-infrared analysis[M]. New York: Marcel Cekker Inc, 1992:93-94.
【4】郑用熙.分析化学中的数理统计方法[M].北京:中国农业出版社, 1986:106-122.