ICP-AES Determination of Scandium in Mg-Sc Alloy
摘 要
提出了采用电感耦合等离子体原子发射光谱法测定镁钪合金中钪的含量。以盐酸(1+1)溶液和过氧化氢溶解样品,选择波长为361.384 nm的谱线作为钪的分析线。钪的发射强度与其质量浓度在20.00 mg·L-1以内呈线性关系,方法的检出限(3s)为2.9×10-4mg·L-1。方法用于镁钪合金样品分析,加标回收率在98.0%~102.0%之间,相对标准偏差(n=6)在0.7%~1.8%之间。
Abstract
An ICP-AES method for the determination of Sc in Mg-Sc alloy was proposed. The sample was dissolved with HCl (1+1) solution and H2O2. The wavelength of 361.384 nm was selected as analytical spectral line for the determination of Sc. Linear relationship between values of emission intensity and mass concentration of Sc was obtained in the range within 20.00 mg·L-1, with detection limit (3s) of 2.9×10-4mg·L-1. Recovery and precision of the method were tested by analyzing 4 Mg-Sc alloy samples by standard addition method, giving values of recovery in the range of 98.0%-102.0% and RSD′s (n=6) in the range of 0.7%-1.8%.
中图分类号 O657.31
所属栏目
基金项目
收稿日期 2010/11/6
修改稿日期
网络出版日期
作者单位点击查看
备注李芬(1963-),女,四川隆昌人,高级工程师,主要研究方向为发射光谱分析和微波消解。
引用该论文: LI Fen,LI Qi-hua,FAN Chao-ying,MA Ying. ICP-AES Determination of Scandium in Mg-Sc Alloy[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2011, 47(7): 816~817
李芬,李启华,樊朝英,马英. 电感耦合等离子体原子发射光谱法测定镁钪合金中钪[J]. 理化检验-化学分册, 2011, 47(7): 816~817
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】辛仁轩.等离子体发射光谱分析[M].北京:化学工业出版社, 2005:9.
【2】陈必友,李启华.工厂分析化验手册[M].2版.北京:化学工业出版社, 2009:550.
【3】GB/T 17417.2-1998稀土矿石化学分析方法 电感耦合等离子体原子发射法测定钪量[S].
【4】范哲锋.离子交换-溶剂萃取ICP-AES法测定红泥中的钪[J].分析试验室, 1999,18(2):83-85.
【5】沈坚.铌钽铁矿中稀土和钪的连续测定[J].稀有金属, 1987(2):107-110.
【6】JJG 768-2005发射光谱仪检定规程[S].
【2】陈必友,李启华.工厂分析化验手册[M].2版.北京:化学工业出版社, 2009:550.
【3】GB/T 17417.2-1998稀土矿石化学分析方法 电感耦合等离子体原子发射法测定钪量[S].
【4】范哲锋.离子交换-溶剂萃取ICP-AES法测定红泥中的钪[J].分析试验室, 1999,18(2):83-85.
【5】沈坚.铌钽铁矿中稀土和钪的连续测定[J].稀有金属, 1987(2):107-110.
【6】JJG 768-2005发射光谱仪检定规程[S].
相关信息