ICP-AES Determination of P, Mn, Ti and Al in Ferro-phosphorus
摘 要
提出了用硝酸-氢氟酸溶解磷铁样品后经高氯酸冒烟除氟,在硝酸(1+99)溶液中,采用电感耦合等离子体原子发射光谱法测定其中的磷、锰、钛和铝等成分。选择波长为213.618,257.610,334.941,308.215 nm的4条谱线依次作为磷、锰、钛和铝测定的分析线。应用此方法分析了4个磷铁样品,其中包括一个国家标准物质GBW 01429,测得结果与化学法的测定结果或与认定值相符。磷、锰、钛和铝测定值的相对标准偏差(n=6)分别为0.49%,0.43%,0.83%,9.0%。
Abstract
Sample of ferro-phosphorus was dissolved in HNO3, HF and HClO4. After fuming with HClO4 to expel fluoride, P, Mn, Ti and Al were determined in HNO3(1+99) solution by ICP-AES using the analytical spectral lines of 213.618, 257.610, 334.941 and 308.215 nm for the 4 elements respectively. In the analysis of 4 substantial samples, including a CRM of GBW 01429, the results found by this method were in consistency with the values found by chemical method or with the certified values. Value of RSD′s (n=6) obtained were 0.49%(P), 0.43%(Mn), 0.83%(Ti) and 9.0%(Al).
中图分类号 O657.31
所属栏目
基金项目
收稿日期 2010/6/28
修改稿日期
网络出版日期
作者单位点击查看
备注应腾远(1971-) 男,浙江宁波人,高级工程师,主要从事进出口矿产品检测及仪器分析工作。
引用该论文: YING Teng-yuan,LIU Wen-fu,Feng Jie. ICP-AES Determination of P, Mn, Ti and Al in Ferro-phosphorus[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2011, 47(8): 955~956
应腾远,刘文甫,冯杰. 电感耦合等离子体原子发射光谱法测定磷铁中磷、锰、钛和铝[J]. 理化检验-化学分册, 2011, 47(8): 955~956
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】王海舟.铁合金分析:上册[M].北京:科学出版社, 2003.
【2】李浩杰,关迪峰,莫蔓,等.磷铁中磷硅钛测定方法的研究[J].检验检疫科学, 2005,15(增刊):29-33.
【3】杜建民,李存根.二安替比林甲烷显色测定磷铁中钛[J].冶金分析, 1996,16(5):54.
【4】吴邦友.ICP-AES法同时测定磷铁中的主含量元素和杂质[J].光谱实验室, 1996,13(3):45-48.
【2】李浩杰,关迪峰,莫蔓,等.磷铁中磷硅钛测定方法的研究[J].检验检疫科学, 2005,15(增刊):29-33.
【3】杜建民,李存根.二安替比林甲烷显色测定磷铁中钛[J].冶金分析, 1996,16(5):54.
【4】吴邦友.ICP-AES法同时测定磷铁中的主含量元素和杂质[J].光谱实验室, 1996,13(3):45-48.
相关信息