GC Determination of 10 Nitrobenzene Homologues in Surface Water with Liquid-Liquid Extraction
摘 要
将水样(200 mL)用正己烷(10 mL)萃取,所得萃取液经无水硫酸钠干燥后供气相色谱分析。用DB-1701色谱柱,温度在110 ℃~210 ℃区间采用程序升温方式进行分离,用电子捕获检测器测定。10种硝基苯类化合物的峰面积与对应的质量浓度在一定范围内呈线性关系,检出限在0.10~2.5 μg·L-1之间。用标准加入法测得10种硝基苯类化合物的回收率在86.4%~96.2%之间,测定值的相对标准偏差(n=7)均小于5%。
Abstract
Water sample (200 mL) was extracted with n-hexane (10 mL), and after dehydration with anhydrous Na2SO4, the extract was used for GC analysis, using DB-1701 chromatographic column for separation in the temperature range from 110 ℃ to 210 ℃ with programmed temperature elevation. ECD was used in the determination. Linear relationships between values of peak area and mass concentration of the 10 nitrobenzene homologues were found in definite ranges, with detection limits in the range of 0.10-2.5 μg·L-1. Tests for recovery and precision were made, giving values of recovery in the range of 86.4%-96.2% and RSD′s (n=7) less than 5%.
中图分类号 O657.7
所属栏目 工作简报
基金项目
收稿日期 2011/5/29
修改稿日期
网络出版日期
作者单位点击查看
联系人作者赵辰(ruke.zc@163.com)
备注赵辰(1985-),男,江苏苏州人,助理工程师,主要从事水质检测工作。
引用该论文: ZHAO Chen,WANG Jin-yu,CHEN Ling-hu,LU Wen-juan. GC Determination of 10 Nitrobenzene Homologues in Surface Water with Liquid-Liquid Extraction[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2012, 48(7): 834~836
赵辰,王晋宇,陈玲瑚,陆文娟. 液液萃取-气相色谱法测定地表水中10种硝基苯类化合物[J]. 理化检验-化学分册, 2012, 48(7): 834~836
被引情况:
【1】周华俏,范磊,田霆, "液-液小体积萃取-气相色谱法测定地表水中硝基苯类化合物",理化检验-化学分册 52, 99-101(2016)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】GB 13194-1991水质 硝基苯、硝基甲苯、硝基氯苯、二硝基甲苯的测定 气相色谱法[S].
【2】GB/T 5750.8-2006生活饮用水标准检验方法 有机物指标[S].
【3】母应锋,杨丽莉,胡恩宇,等.一滴溶剂微萃取-毛细管气相色谱法分析水中的七种硝基苯类化合物[J].色谱, 2007,25(6):876-880.
【4】苏晓燕.固相萃取-毛细管气相色谱法测定地表水中硝基苯类化合物[J].环境监测管理与技术, 2008,20(2):30-34.
【2】GB/T 5750.8-2006生活饮用水标准检验方法 有机物指标[S].
【3】母应锋,杨丽莉,胡恩宇,等.一滴溶剂微萃取-毛细管气相色谱法分析水中的七种硝基苯类化合物[J].色谱, 2007,25(6):876-880.
【4】苏晓燕.固相萃取-毛细管气相色谱法测定地表水中硝基苯类化合物[J].环境监测管理与技术, 2008,20(2):30-34.
相关信息