GC-MS/MS Determination of Polychlorinated Biphenyls in Water
摘 要
采用气相色谱-串联质谱法测定水中19种多氯联苯的含量。样品用正己烷萃取两次,有机相吹氮浓缩至1 mL。通过HP-5MS色谱柱分离,串联质谱测定。19种多氯联苯的检出限在0.40~0.51 ng·L-1之间。以纯水为基体,加入19种多氯联苯标准溶液进行回收试验,测得回收率在74.0%~109%之间,测定值的相对标准偏差(n=7)在6.0%~11%之间。
Abstract
GC-MS/MS was applied to the determination of 19 polychlorinated biphenyls in water. The sample was extracted twice with n-hexane, which was concentrated to 1 mL by N2-blowing. Separated on HP-5MS column, and determined by MS/MS. Values of limit of detection found were in the range of 0.40-0.51 ng·L-1. Tests for recovery were made by addition of mixed standard of the 19 polychlorinated biphenyls to pure water as matrix. Values of recovery found were in the range of 74.0%-109%, with values of RSD′s (n=7) in the range of 6.0%-11%.
中图分类号 O657.63
所属栏目 工作简报
基金项目 南宁市科技局项目(201102083C)
收稿日期 2012/11/22
修改稿日期
网络出版日期
作者单位点击查看
联系人作者范磊(funly100@163.com)
备注范磊(1980- ),男,安徽太和人,工程师,硕士,主要从事环境监测分析工作。
引用该论文: FAN Lei,HUANG Su-hua,TIAN Ting,HE Ri-an,ZHOU Hua-qiao,HUANG Ke-zun. GC-MS/MS Determination of Polychlorinated Biphenyls in Water[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2013, 49(12): 1479~1482
范磊,黄素华,田霆,何日安,周华俏,黄可尊. 气相色谱-串联质谱法测定水中多氯联苯[J]. 理化检验-化学分册, 2013, 49(12): 1479~1482
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】赵荣飚,秦占芬,赵汝松,等.水和生物样品中痕量多氯联苯的分析方法研究[J].分析化学, 2005,33(10):1361-1365.
【2】杨佳佳,吴淑琪,佟玲.多氯联苯的环境特性及分析测试进展[J].岩矿测试, 2009,28(5):444-451.
【3】劳燕文,杨益林.气相色谱法测定蔬菜中22种多氯联苯残留量[J].理化检验-化学分册, 2010,46(11):1253-1255.
【4】王娜.液-液萃取富集-气相色谱法测定水中有机氯农药和多氯联苯[J].理化检验-化学分册, 2011,47(3):327-330.
【5】俞是聃.快速溶剂萃取-气相色谱-质谱联用法测定土壤中多氯联苯Aroclor系列[J].理化检验-化学分册, 2009,45(3):288-292.
【6】佟玲,黄园英,张玲金,等.气相色谱-质谱法测定土壤中有机氯农药及多氯联苯[J].理化检验-化学分册, 2009,45(7):858-861.
【7】施跃锦,蔡美强,金米聪.超声波辅助离子液体顶空液相微萃取-气相色谱-质谱法测定水中多氯联苯[J].理化检验-化学分册, 2011,47(6):629-632.
【8】杨佳佳,吴淑琪,佟玲,等.离子阱串联质谱法测定土壤及沉积物中的有机氯农药与多氯联苯[J].分析测试学报, 2011,30(4):374-380.
【9】曲健,郑兴宝.有机氯农药和多氯联苯测定的样品净化方法[J].环境监测管理与技术, 2008,20(5):59-61.
【10】EPA 505Analysis of organohalide pesticides and commercial polychlorinated biphenyl (PCB) products in water by microextraction and gas chromatography[S].
【11】EPA 8082Polychlorinated biphenyls (PCB′s) by gas chromatography[S].
【12】胡恩宇,杨丽莉,王美飞,等.气相色谱法同时测定水中28种多氯联苯单体[J].环境监测管理与技术, 2010,22(1):44-48.
【2】杨佳佳,吴淑琪,佟玲.多氯联苯的环境特性及分析测试进展[J].岩矿测试, 2009,28(5):444-451.
【3】劳燕文,杨益林.气相色谱法测定蔬菜中22种多氯联苯残留量[J].理化检验-化学分册, 2010,46(11):1253-1255.
【4】王娜.液-液萃取富集-气相色谱法测定水中有机氯农药和多氯联苯[J].理化检验-化学分册, 2011,47(3):327-330.
【5】俞是聃.快速溶剂萃取-气相色谱-质谱联用法测定土壤中多氯联苯Aroclor系列[J].理化检验-化学分册, 2009,45(3):288-292.
【6】佟玲,黄园英,张玲金,等.气相色谱-质谱法测定土壤中有机氯农药及多氯联苯[J].理化检验-化学分册, 2009,45(7):858-861.
【7】施跃锦,蔡美强,金米聪.超声波辅助离子液体顶空液相微萃取-气相色谱-质谱法测定水中多氯联苯[J].理化检验-化学分册, 2011,47(6):629-632.
【8】杨佳佳,吴淑琪,佟玲,等.离子阱串联质谱法测定土壤及沉积物中的有机氯农药与多氯联苯[J].分析测试学报, 2011,30(4):374-380.
【9】曲健,郑兴宝.有机氯农药和多氯联苯测定的样品净化方法[J].环境监测管理与技术, 2008,20(5):59-61.
【10】EPA 505Analysis of organohalide pesticides and commercial polychlorinated biphenyl (PCB) products in water by microextraction and gas chromatography[S].
【11】EPA 8082Polychlorinated biphenyls (PCB′s) by gas chromatography[S].
【12】胡恩宇,杨丽莉,王美飞,等.气相色谱法同时测定水中28种多氯联苯单体[J].环境监测管理与技术, 2010,22(1):44-48.
相关信息