Uncertainty Evaluation on Tensile Strength Testing Results of Flexible Cellular Polymeric Materials
摘 要
依据GB/T 6344-2008测定了聚氨酯软泡的拉伸强度,并对拉伸强度测定结果的不确定度进行了分析评定。结果表明: 该聚氨酯软泡的拉伸强度为142 kPa时,测定结果的扩展不确定度为2 kPa, 包含因子k=2。
Abstract
According to the test method in GB/T 6344-2008, the tensile strength of flexible polyurethane foam was determined. The main sources of uncertainty resulted from the determination process were discussed and calculated. The results show the tensile strength of the flexible polyurethane foam was 142 kPa,and the expanded standard uncertainty of the testing results was 2 kPa when coverage factor k=2.
中图分类号 TQ323.8
所属栏目 试验技术与方法
基金项目
收稿日期 2011/6/13
修改稿日期
网络出版日期
作者单位点击查看
备注杜鹏(1983-), 女, 助理工程师, 硕士。
引用该论文: DU Peng,CHEN Xing-long,JU Wen-jun,ZHANG Shao-min. Uncertainty Evaluation on Tensile Strength Testing Results of Flexible Cellular Polymeric Materials[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2012, 48(2): 106~108
杜鹏,陈兴龙,巨文军,张少民. 软质泡沫聚合材料拉伸强度测定结果的不确定度评定[J]. 理化检验-物理分册, 2012, 48(2): 106~108
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】CNAS-CL01: 2006检测和校准实验室能力认可准则[S].
【2】倪育才.实用测量不确定度评定[M].北京:中国计量出版社,2004.
【3】曾新榕, 吴晓冰. 国内软质聚氨酯泡沫塑料产品质量现状分析[J]. 合成树脂及塑料,1991(1):42-46.
【4】李慎安.测量不确定度评定的简化评定[M].北京:中国计量出版社,2004.
【5】JJF 1059-1999测量不确定度评定与表示[S].
【6】CNAS-CL07: 2011测量不确定度评估和报告通用要求[S].
【2】倪育才.实用测量不确定度评定[M].北京:中国计量出版社,2004.
【3】曾新榕, 吴晓冰. 国内软质聚氨酯泡沫塑料产品质量现状分析[J]. 合成树脂及塑料,1991(1):42-46.
【4】李慎安.测量不确定度评定的简化评定[M].北京:中国计量出版社,2004.
【5】JJF 1059-1999测量不确定度评定与表示[S].
【6】CNAS-CL07: 2011测量不确定度评估和报告通用要求[S].