Calculation of Cross-section Areas of Circular Tube Longitudinal Arc Specimens
摘 要
针对GB/T 228.1-2010给出的3个计算圆管纵向弧形试样横截面积的公式, 在计算上且存在着不便或限制的问题, 笔者采用数学推导的方法建立了一个统一式, 即S0 =0.017 44 a(D-a)·arcsinbD-a。应用举例结果表明: 采用该公式计算圆管纵向弧形试样的横截面积不仅计算简单, 而且结果准确。
Abstract
To solve the inconvenience or restricted problem of three formulas in GB/T 228.1-2010 to calculate cross-section areas of longitudinal arc specimens cutting from the circular tubes, an uniform formula was established by mathematical deducing method, and that is S0 =0.017 44 a(D-a)·arcsinbD-a. The application examples results show that using this formula to calculate the cross-section areas of the circular tube longitudinal arc specimens, not only the calculation is simple, but also the result is accuracy.
中图分类号 TG115.5+2
所属栏目 实践经验
基金项目
收稿日期 2011/12/27
修改稿日期
网络出版日期
作者单位点击查看
备注李庆山(1940-), 男, 高级工程师。
引用该论文: LI Qing-shan. Calculation of Cross-section Areas of Circular Tube Longitudinal Arc Specimens[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2012, 48(10): 672~673
李庆山. 圆管纵向弧形试样横截面积的计算[J]. 理化检验-物理分册, 2012, 48(10): 672~673
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】GB/T 228.1-2010金属材料 拉伸试验 第1部分: 室温试验方法[S].