Evaluation of Uncertainty on Measurement Results for Tensile Test of Metal
摘 要
GB/T 228.1—2010标准中修改了评定拉伸试验测量不确定度的方法。通过测定卷板的拉伸性能, 对规定总延伸强度和抗拉强度的性能指标进行了测量不确定度评定, 分析了不确定度来源, 剔除测量结果中的离群值, 提供了一种拉伸试验测量结果不确定度评定的可行方法, 并对评定过程中的几个问题进行了探讨。
Abstract
The method for evaluation of uncertainty on measurement results for tensile test was modified in GB/T 228.1—2010standard.Basing on testing the tensile capability of steel plate, the uncertainty of measurement resultsfor proof strength of total elongation performance and tensile strength performance was evaluated, the source ofuncertainty was analyzed, the outliers of the measurement results was rejected, a feasible method of evaluation ofuncertainty on measurement results for tensile test was provided, and several problems raised in the process ofevaluation were discussed.
中图分类号 TG142.1
所属栏目 试验技术与方法
基金项目
收稿日期 2012/2/16
修改稿日期
网络出版日期
作者单位点击查看
备注刘通(1985—), 男, 助理工程师, 学士。
引用该论文: LIU Tong,LI Ke,ZHANG Sheng-guang,WANG Kun-xian. Evaluation of Uncertainty on Measurement Results for Tensile Test of Metal[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2012, 48(11): 739~742
刘通,李珂,张圣光,王坤显. 金属材料拉伸试验测试结果不确定度的评定[J]. 理化检验-物理分册, 2012, 48(11): 739~742
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】GB/T 228.1—2010 金属材料 拉伸试验第一部分: 室温试验方法[S].
【2】CNAS—CL01检测和校准实验室能力认可准则(ISO/IEC 17025: 2005)[S].
【3】JJF 1059—1999 测量不确定度评定与表示[S].
【4】倪育才.实用测量不确定度评定[M].北京: 中国计量出版社, 2010.
【5】JJG 144—1992 标准测力仪检定规程[S].
【6】JJF 1103—2003 万能试验机计算机数据采集系统[S].
【2】CNAS—CL01检测和校准实验室能力认可准则(ISO/IEC 17025: 2005)[S].
【3】JJF 1059—1999 测量不确定度评定与表示[S].
【4】倪育才.实用测量不确定度评定[M].北京: 中国计量出版社, 2010.
【5】JJG 144—1992 标准测力仪检定规程[S].
【6】JJF 1103—2003 万能试验机计算机数据采集系统[S].
相关信息