Analysis on Leakage Cause of TP304 Stainless Steel Tube in Gland Steam Condenser of USC Units
摘 要
通过宏观检验、化学成分分析、拉伸试验、压扁试验、晶间腐蚀试验、金相检验、扫描电镜及能谱分析等方法,对某电厂汽轮机轴封冷却器TP304不锈钢管的泄漏问题进行了分析。结果表明: TP304不锈钢管在外表面残余拉应力和蒸汽中Cl-, S2-的联合作用下, 经过一定时间因发生严重应力腐蚀导致管子开裂。对此, 提出了消除TP304不锈钢焊管表面残余应力、严格控制汽水品质、降低有害离子含量等建议。
Abstract
The leakage cause of TP304 stainless steel tube in gland steam condenser of USC units was investigated by means of macroscopic observation, chemical composition analysis, tensile test, flattening test, intergranular corrosion test, metallographic examination, SEM and EDS analysis. The results showed that the leakage of TP304 stainless steel tube was caused by stress corrosion under the joint action of surface residual stress and corrosive medium Cl-, S2- in steam. For this, preventive measures, such as relieving surface residual stress, strictly controlling boiler steam-water quality, reducing the content of harmful irons, have been put forward.
中图分类号 TK223.3 TG115
所属栏目 质量控制与失效分析
基金项目
收稿日期 2012/8/14
修改稿日期
网络出版日期
作者单位点击查看
备注田晓(1985-), 女, 工程师, 工学硕士。
引用该论文: TIAN Xiao,XIAO Guo-hua,LI Yi-min,YANG Bai-xun. Analysis on Leakage Cause of TP304 Stainless Steel Tube in Gland Steam Condenser of USC Units[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2013, 49(1): 64~67
田晓,肖国华,李益民,杨百勋. 超临界机组轴封冷却器TP304不锈钢管泄漏原因分析[J]. 理化检验-物理分册, 2013, 49(1): 64~67
被引情况:
【1】陈汉明,方可伟, "某汽轮机抽汽疏水弯管泄漏失效分析",理化检验-物理分册 51, 593-595(2015)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】吴剑.不锈钢的腐蚀破坏与防蚀技术:(四)应力腐蚀[J].腐蚀与防护,1997,18(4):39-40.
【2】张国华,李敬高.奥氏体不锈钢应力腐蚀分析研究[J].焊接技术,2002,31(6):53-54.
【3】汪德良,李志刚,柯于进,等.超超临界参数机组的水汽品质控制[J].中国电力,2005,38(8): 57-61.
【4】夏之秋,顾伟生,朱世根,等.TP304不锈钢薄壁管的表面残余应力[J].理化检验-物理分册,2010,46(6): 356-359.