A Special Kind of Delayed Echo
摘 要
超声波检测铝合金方形锻件时,经常会在1次底波后出现一种位置固定的特殊回波。通过对直探头发射的声束在零件入射面和背面的折射和反射行为进行分析,发现由于存在小角度斜入射而引起波型转换,会在1次底波和2次底波之间固定的位置出现一种迟到波。在使用2次波探伤法或者检测带台阶的零件时,应避免把该迟到波误判为缺陷波。
Abstract
A special fixed echo after the fist back reflection could be frequently received during inspecting quadrate aluminum forging. After carefully analyzing the refraction and reflection of ultrasonic beam of normal probe at test surface and back surface, we found that small angle incident led to wave form conversion, and wave form conversion led to a special kind of fixed delayed echo between first and second back reflection. When inspecting part with step or using double traverse technique, full attention should be paid to avoid mistreating this kind of delayed echo as flaw echo.
中图分类号 TG115.28
所属栏目 实践经验
基金项目
收稿日期 2010/8/15
修改稿日期
网络出版日期
作者单位点击查看
备注侯胜利(1980-),男,工程师。从事航空产品的超声波和渗透检测。
引用该论文: HOU Sheng-Li. A Special Kind of Delayed Echo[J]. Nondestructive Testing, 2011, 33(6): 35~37
侯胜利. 一种特殊的迟到波[J]. 无损检测, 2011, 33(6): 35~37
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】李克明,刘德荣,张志永,等.超声波探伤[M].北京:电力工业出版社,1980:130-131.
【2】李家伟,陈积懋.无损检测手册[M].北京:机械工业出版社,2002:220.
【2】李家伟,陈积懋.无损检测手册[M].北京:机械工业出版社,2002:220.
相关信息