The In-situ Phased Array Ultrasonic Testing of the Last Stage Blade About the MARKII Low Pressure Rotor
摘 要
大亚湾核电站汽轮机转子末级叶片是采用GEC-A设计制造的MARKII型叶片枞树型叶根。由于GEC-A未改进前的末级叶片在其它电厂发现过裂纹,大亚湾核电站很早就开始实施反馈性预防检查,但需要拆除末级叶片,而一次拆装检查需要8~9 d,成为核电厂常规换料大修中的关键瓶径,并可能产生因拆卸而带来的机械损伤风险。因此,找到延长低压缸拆装叶片的周期的方法,将可以实现在保证核电厂汽轮机组可靠性的同时进一步提高经济性。通过多年的调研及试验,相控阵超声波原位检查技术可以满足此目的,并已在现场得到成功应用。
Abstract
In Daya Bay nuclear plant, the type of the last stage blade of turbine rotor is MARKⅡ vertical tree root, which is designed by GEC-A. In some plants, cracks were found on the rotor blades of old type, which were not improved before by GEC-A. For that reason, Daya Bay nuclear plant began feedback preventive inspection in a very early time. But there is a problem that it has to tear down all the rotor blades before inspection each time, so the inspection will cost about 8~9 days and become the critical path of the refueling outage, whats more, it may cause the risk of mechanical damage. Therefore, to extend the cycle time of the low-pressure cylinder blades disassembly can further improve the economy of the steam turbine and keep the nuclear power plant steam turbine maintaining a reliable. Through years of researches and experiments, in-situ phased array ultrasonic inspection techniques can meet the requirement, and it has been successfully used practically.
中图分类号 TG115.28
所属栏目 实践经验
基金项目
收稿日期 2011/5/20
修改稿日期
网络出版日期
作者单位点击查看
备注范岩成(1978-),男,高级工程师,硕士,主要从事核电厂在役检查工作。
引用该论文: FAN Yan-Cheng. The In-situ Phased Array Ultrasonic Testing of the Last Stage Blade About the MARKII Low Pressure Rotor[J]. Nondestructive Testing, 2012, 34(3): 69~72
范岩成. MARKII型低压转子末级叶片原位叶根的超声相控阵检查[J]. 无损检测, 2012, 34(3): 69~72
被引情况:
【1】薛利杰,刘晴岩,方雨,左延田,严晓东, "特种设备在役螺栓超声相控阵检测成像影响因素",无损检测 38, 6-10(2016)
【2】范岩成,徐金利, "MARKⅡ型叶片叶根相控阵超声波检查信号的分析",无损检测 35, 65-69(2013)