Research of Gathering Focus Wire for Rectifying Electron Locus Based on the Focusing Coil for X Ray Tube Electron Beam Trajectory Correction Technology
摘 要
X射线管道爬行器在长输管道环焊缝射线检测中得到越来越广泛的应用。其在西气东输二线大口径长输管道的应用中,出现周向锥靶X射线发生器偏靶现象,致使周向X射线场强不均匀,拍摄的底片黑度差异大。对此提出了将聚焦线圈应用在周向锥靶X射线发生器中,以纠正电子束轨迹的方法。通过分析,试验达到了周向上场强均匀的目的。在后续的长输管道射线检测应用施工中收到良好效果。
Abstract
X ray crawler in long distance pipeline girth welding seam X-ray detection is widely used. During the application in the second west to East Gas Pipeline Project of large diameter pipeline, partial target phenomenon was observed for circumferential conical target X ray generator, causing the circumferential X ray intensity inhomogeneity and film densiting difference. To solve this problem, the focusing coil was used in the circumferential conical target X ray generator to correct the trajectory ofelectron beam. Through the analysis of the experiment, circumferential field intensity reached the purpose of uniform. Application in the follow-up of the long distance pipeline construction in radiographic testing received good results.
中图分类号 TG115.28
所属栏目 仪器研制
基金项目
收稿日期 2011/10/19
修改稿日期
网络出版日期
作者单位点击查看
备注张金光(1975-),男,工程师,一级建造师,从事长输管道工程无损检测施工工作。
引用该论文: ZHANG Jin-Guang,LI Dong-Xue,MA Chun-Qing. Research of Gathering Focus Wire for Rectifying Electron Locus Based on the Focusing Coil for X Ray Tube Electron Beam Trajectory Correction Technology[J]. Nondestructive Testing, 2012, 34(6): 62~64
张金光,李冬雪,马春青. 聚焦线圈对管道爬行器X射线管电子束轨迹的纠正作用[J]. 无损检测, 2012, 34(6): 62~64
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】杨克俊.电磁兼容原理与设计技术[M].北京:人民邮电出版社,2005
【2】刘鹏程,邱扬.电磁兼容原理及技术[M].北京:高等教育出版社,1993.
【3】JJG 40—2001X射线探伤机[S].
【4】JB/T 4730—2005承压设备无损检测[S].
【2】刘鹏程,邱扬.电磁兼容原理及技术[M].北京:高等教育出版社,1993.
【3】JJG 40—2001X射线探伤机[S].
【4】JB/T 4730—2005承压设备无损检测[S].
相关信息