X and γ-Ray Test Analysis of Fillet Weld Based on Linear Array Detector
摘 要
为了检测管子-管板角焊缝内部缺陷,提出了基于线阵探测器的管子-管板角焊缝射线数字检测方法。介绍了线阵列探测器成像原理,通过对管子-管板角焊缝试件的射线数字透射成像试验,分析了线阵列探测器在X和γ射线照射下的图像特点。试验表明,相比X射线,利用γ射线采集的图像质量稍差,并且整体灰度偏暗,采集时间较长。得出了影响线阵列探测器γ射线数字图像质量的一些关键因素,为线阵列探测器应用于γ射线提供了试验及应用依据。
Abstract
To test the tube-to-tubesheet fillet weld internal defects, the paper proposed the ray digital detection method which was based on the linear array detector. This paper introduced the imaging principle of the linear array detector, and analyzed the image characteristics of the linear array detector of both X and γ-ray irradiation by the radiography test of the tube-to-tubesheet fillet weld specimens. The test showed that compared to the X-ray, γ-ray collected images quality was lower, and overall gray was darker, acquisition time was longer. Some of the key factors were obtained that affected the γ-ray linear array detector digital image quality. At the same time this paper provided an experimental and application basis for which the linear array detector was used in γ-ray test.
中图分类号 TG115.28
所属栏目 试验研究
基金项目 质检公益性行业科研专项资助项目(200910092)
收稿日期 2011/9/19
修改稿日期
网络出版日期
作者单位点击查看
备注丁克勤(1968-),男,博士,主要从事特种设备检测技术研究。
引用该论文: DING Ke-Qin,CHEN Guang,ZHANG Xu. X and γ-Ray Test Analysis of Fillet Weld Based on Linear Array Detector[J]. Nondestructive Testing, 2012, 34(9): 27~29
丁克勤,陈光,张旭. 基于线阵探测器的X和γ射线角焊缝检测试验分析[J]. 无损检测, 2012, 34(9): 27~29
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】姚炫东,王元华.热交换器管子-管板角焊缝的射线检测[J].无损检测,2003,12(12):647.
【2】李衍.压力容器无损检测—射线检测技术(Ⅱ)[J].无损检测,2004,26(3):132.
【3】屈国普,凌球,郭兰英,等.X射线线阵列探测器数字图像的非均匀性原因分析[J].核电子学与探测技术,2003,23(5):414-416.
【4】向东,郭兰英,凌球,等.X射线线阵探测器的扫描成像研究[J].南华大学学报,2006,20(1):23-38.
【5】何山林,马跃洲,陈光,等.线扫描X射线数字成像技术在螺旋焊管检测中的应用[J].焊接,2006(11):56-59.
【6】孙朝明,李强,王增勇,等.CMOS探测器在射线检测中的应用[J].仪器仪表学报,2007,28(4):420-422.
【7】丁克勤,陈光,梁丽红,等.管子-管板焊接接头射线数字成像自动检测系统[J].无损检测,2009,6(6):647.
【8】陈明,马跃洲,陈光. X射线线阵实时成像焊缝缺陷检测方法[J].焊接学报,2007,28(6):81-84.
【2】李衍.压力容器无损检测—射线检测技术(Ⅱ)[J].无损检测,2004,26(3):132.
【3】屈国普,凌球,郭兰英,等.X射线线阵列探测器数字图像的非均匀性原因分析[J].核电子学与探测技术,2003,23(5):414-416.
【4】向东,郭兰英,凌球,等.X射线线阵探测器的扫描成像研究[J].南华大学学报,2006,20(1):23-38.
【5】何山林,马跃洲,陈光,等.线扫描X射线数字成像技术在螺旋焊管检测中的应用[J].焊接,2006(11):56-59.
【6】孙朝明,李强,王增勇,等.CMOS探测器在射线检测中的应用[J].仪器仪表学报,2007,28(4):420-422.
【7】丁克勤,陈光,梁丽红,等.管子-管板焊接接头射线数字成像自动检测系统[J].无损检测,2009,6(6):647.
【8】陈明,马跃洲,陈光. X射线线阵实时成像焊缝缺陷检测方法[J].焊接学报,2007,28(6):81-84.