The Selection of Fluorescence Penetrant Inspection Emulsification Parameters for Nickel-chrome Layer
摘 要
镍铬镀层的裂纹缺陷是造成镀镍铬零件功能失效的主要原因,对此类零件最为有效的无损检测方法是亲水性后乳化的荧光渗透检测。如何选择乳化剂浓度、乳化时间等参数,是亲水性后乳化荧光渗透检测成功的关键。通过对镍铬镀层裂纹标准试片荧光渗透检测时在不同乳化时间、乳化剂浓度参数下进行的试验,选择较为合理的乳化参数,达到符合标准要求的检测灵敏度。
Abstract
The crack defect of nickel chrome plating layer is the main cause of the part failure. For this type of part, the most effective nondestructive test method is fluorescence penetrant inspection-hydrophilic post emulsification method. How to choose the concentration of emulsifier and emulsifier time is the key to make the hydrophilic post emulsification succeed. Through testing on standard test piece of nickel chrome plating layer under different emulsifier time and emulsifier concentration, the proper emulsifier parameters were selected to reach the detection sensitivity complying with the requirement.
中图分类号 TG115.28
所属栏目 实践经验
基金项目
收稿日期 2012/8/24
修改稿日期
网络出版日期
作者单位点击查看
备注黄瑞龙(1964-),男,工程师,主要从事渗透检测、涡流检测的技术工作。
引用该论文: HUANG Rui-Long. The Selection of Fluorescence Penetrant Inspection Emulsification Parameters for Nickel-chrome Layer[J]. Nondestructive Testing, 2013, 35(7): 54~55
黄瑞龙. 镀镍铬零件荧光渗透检测乳化参数的选择[J]. 无损检测, 2013, 35(7): 54~55
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】林猷文,任学冬.渗透检测[M].北京:机械工业出版社,2004.
【2】PS79-2010 Fluorescent Penetrant Inspection[S].
【3】NDT3-2006 Non-destructive Testing Inspection of Ground Chromium Plated Parts[S].
【2】PS79-2010 Fluorescent Penetrant Inspection[S].
【3】NDT3-2006 Non-destructive Testing Inspection of Ground Chromium Plated Parts[S].