冷凝液pH对消声器用409不锈钢腐蚀行为的影响
          
Effect of pH on Condensate Corrosion of Type 409 Stainless Steel for Automotive Mufflers

摘    要
采用极化曲线和电化学阻抗谱研究了消声器用409不锈钢在不同pH冷凝液中的腐蚀行为,并用X射线光电子能谱(XPS)分析了pH对409不锈钢钝化膜化学组成的影响.结果表明,试样在冷凝液pH为2时处于活化腐蚀状态,而冷凝液pH不低于3时处于钝化状态;在酸性条件下钝化膜富含铬的化合物、缺陷较多,试样腐蚀阻力相对较小,而在中/碱性条件下钝化膜富含铁的化合物、缺陷较少,试样腐蚀阻力较大.
标    签 汽车消声器   不锈钢   冷凝液腐蚀   pH   钝化膜   automotive muffler   stainless steel   condensate corrosion   pH   passivation film  
 
Abstract
The corrosion behavior of type 409 stainless steel in simulated muffler condensates with different pH values was studied by polarization curves and electrochemical impedance spectroscopy (EIS).The composition of passive films formed on 409 SS surfaces was analyzed by XPS.The results showed that 409 SS was in active corrosion state as pH was equal to 2,while it changed to passive state as pH increased to 3.The passive films formed under acidic conditions enriched in Cr-compounds with many defects while they enriched in Fe-compounds under neutral and alkaline conditions with less defects.As a result,409 SS showed much higher corrosion resistance in the neutral and alkaline condensate solutions than in the acidic ones.

中图分类号 TG174

 
  中国光学期刊网论文下载说明


所属栏目 试验研究

基金项目 国家自然科学基金(51134010)

收稿日期 2014/6/21

修改稿日期

网络出版日期

作者单位点击查看


备注李谋成(1970-),研究员,博士,从事腐蚀电化学相关研究.

引用该论文: MA Rong-yao,LI Mou-cheng,SHEN Jia-nian. Effect of pH on Condensate Corrosion of Type 409 Stainless Steel for Automotive Mufflers[J]. Corrosion & Protection, 2015, 36(5): 448


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】阮玮慧,王士栋,李谋成,等.409不锈钢在消声器冷凝液中的腐蚀行为[J].腐蚀科学与防护技术,2012,24(4):301-305.
 
【2】SATO E,TANOUE T.Present and future trends of materials for automotive exhaust system[J].Nippon Steel Technical Report,1995,64:13-19.
 
【3】INOUE Y,KIKUCHI M.Present and future trends of stainless steel for automotive exhaust system[J].Nippon Steel Technical Report,2003,88:62-69.
 
【4】HONGYUN B,YONG W,XIN L.Application and failure evaluation of ferritic stainless steels for automotive exhaust systems[J].Baosteel Technical Research,2010,4(1):10-14.
 
【5】MIYAZAKI A,HIRASAWA J,SATOH S.Advanced stainless steels for stricter regulations of automotwe exhaust gas[J].Kawasaki Steel Technical Report,2000,43:21-28.
 
【6】LI M C,WANG S D,MA R Y,et al.Effect of cyclic oxidation on electrochemical corrosion of type 409 stainless steel in the simulated muffler condensates[J].Journal of Solid State Electrochemistry,2012,16(9):3059-3067.
 
【7】XU J,XIN S S,HAN P H,et al.Cerium chemical conversion coatings for corrosion protection of stainless steels in hot seawater environments[J].Materials and Corrosion,2013,64(7):619-624.
 
【8】FREIRE L,CARMEZIM M J,FERREIRA M G S,et al.The passive behaviour of AISI 316 in alkaline media and the effect of pH:A combined electrochemical and analytical study[J].Electrochimica Acta,2010,55(21):6174-6181.
 
【9】FATTAH-ALHOSSEINI A,GOLOZAR M A,SAATCHI A,et al.Effect of solution concentration on semiconducting properties of passive films formed on austenitic stainless steels[J].Corrosion Science,2010,52(1):205-209.
 
【10】CARMEZIM M J,SIMOES A M,MONTEMOR M F,et al.Capacitance behaviour of passive films on ferritic and austenitic stainless steel[J].Corrosion Science,2005,47(3):581-591.
 
【11】KUMAGAI M,MYUNG S T,KUWATA S,et al.Corrosion behavior of austenitic stainless steels as a function of pH for use as bipolar plates in polymer electrolyte membrane fuel cells[J].Electrochimica Acta,2008,53(12):4205-4212.
 
【12】HAKIKI N B,BOUDIN S,RONDOT B,et al.The electronic structure of passive films formed on stainless steels[J].Corrosion Science,1995,37(11):1809-1822.
 
【13】李成涛,李晓刚,程学群,等.316L不锈钢、690合金在氢氧化钠溶液中的电化学性能[J].腐蚀与防护,2011(4):252-255.
 
【14】王超,支玉明,盛敏奇,等.AISI304不锈钢钝化膜在电解质溶液中腐蚀时的半导体性质[J].腐蚀与防护,2009,30(6):369-372.
 
【15】LUO H,DONG C F,LI X G,et al.The electrochemical behaviour of 2205 duplex stainless steel in alkaline solutions with different pH in the presence of chloride[J].Electrochimica Acta,2012,64:211-220.
 
【16】FREIRE L,CARMEZIM M J,FERREIRA M G S,et al.The electrochemical behaviour of stainless steel AISI 304 in alkaline solutions with different pH in the presence of chlorides[J].Electrochimica Acta,2011,56(14):5280-5289.
 
【17】刘欣,黄印俊,刘学庆,等.铝合金牺牲阳极的镀锌处理及其电化学性能[J].腐蚀与防护,2012,12(1):1-4.
 
相关信息
   标题 相关频次
 中/低铬铁素体不锈钢在消声器冷凝液中的腐蚀行为
 5
 201型不锈钢在酸性食物模拟环境中的腐蚀行为
 4
 钝化膜完整性对不锈钢海洋大气腐蚀的影响及其质检方法
 4
 某海上平台316L不锈钢液控管线泄漏原因
 4
 Cl-,CO2和微量H2S共存时13Cr不锈钢的腐蚀性能
 3
 凝汽器材料的耐磨蚀性能及电化学性能
 3
 硼酸缓冲溶液pH对黄铜表面钝化膜电化学性能的影响
 3
 2205双相钢临界点蚀温度测量方法的比较
 2
 303Cu不锈钢在拉拔及机加工时开裂原因
 2
 304、316不锈钢和Inconel 617镍基合金在硝酸熔盐中的腐蚀行为
 2
 304L不锈钢疏水管焊接接头的腐蚀疲劳行为
 2
 304不锈钢表面锈蚀原因分析
 2
 304不锈钢大小头短期内开裂原因分析
 2
 304不锈钢点腐蚀的声发射检测
 2
 304不锈钢焊缝的相控阵超声检测
 2
 304不锈钢酸性化学镀镍的工艺研究
 2
 316L,317L和904L不锈钢在含溴离子醋酸溶液中的腐蚀行为
 2
 316L不锈钢人孔盖板爆裂原因分析
 2
 316L不锈钢在FeCl3溶液中点蚀行为的电化学噪声检测
 2
 316L不锈钢在有机胺脱硫溶液中的耐蚀性
 2
 445铁素体不锈钢内胆水箱的加工性能和耐蚀性
 2
 AISI304不锈钢钝化膜在电解质溶液中腐蚀时的半导体性质
 2
 AISI316L和SAF2205不锈钢在含溴醋酸溶液中腐蚀行为的研究
 2
 CdSe-TiO2复合材料对304不锈钢的光生阴极保护性能
 2
 Cr12不锈钢零件表面裂纹分析
 2
 GIS用不锈钢板簧断裂分析与预防
 2
 MLA系统在不锈钢非金属夹杂物分析中的应用
 2
 NaCl和Na2S混合溶液pH对SA516Gr70N钢应力腐蚀开裂的影响
 2
 NaOH污染土对X70钢早期腐蚀的影响
 2
 PTA装置碱洗对设备腐蚀开裂影响讨论
 2