Corrosion Failure Analysis of Inner Al Layers of 35 kV Aluminium Cable Steel Reinforced (ACSR) Conductors
摘 要
采用SEM和EDS对福建省某海岛上失效的35 kV钢芯铝绞线进行表面和断口的形貌观察和成分分析.结果表明,表面主要由铝,Al(OH)3和Al5(CO3)3(OH)13·xH2O等物相组成,组成的元素除了铝、氧外,还含有碳、硅、硫、氯、钠、镁、钙等.碳、硅等元素集中在表面以及距表面250~500 μm处.海洋大气、CO2和尘埃等腐蚀介质导致内层铝股线严重腐蚀,大量腐蚀产物粘附在基体上,表面上有以腐蚀区域为核心的发散裂纹.在腐蚀、振动和线张力的作用下,疲劳裂纹扩展带呈现半椭圆轮廓线,最终导致材料断裂.
Abstract
The fracture surface of corroded inner Al layers of 35 KV aluminium cable steel reinforced (ACSR) conductors acrossing the 81# and 82# towers used on an island in Fujian Province was studied by SEM and EDS.The results indicated that the fatigue fracture surface was mainly composed of phases of Al,Al(OH)3 and Al5(CO3)3(OH)13·xH2O.In addition to the Al and O,C,Si,S,Cl,Na,Mg,Ca,etc existed in the surface.C,Si and other elements appeared primarily on the surface and areas about 250 μm to 500 μm away from the surface.The corrosive media such as marine atmosphere,CO2 and dust caused severe corrosion of the inner aluminum stranded wires.A large number of corrosion products adhered on the substrate and there were some divergent cracks centred on the corrosion areas.Under the effect of corrosion,aeolian vibration and line tension,corrosion areas were naturally turned into multiple corrosion fatigue sources and fatigue cracks propagated with half elliptical contour line,and eventually led the materials to fracture.
中图分类号 TG172.3 DOI 10.11973/fsyfh-201506020
所属栏目 失效分析
基金项目 国网福建省电力有限公司科技项目(13KJ080201C;2010720130000)
收稿日期 2014/5/16
修改稿日期
网络出版日期
作者单位点击查看
备注陈云翔(1983-),工程师,博士,从事电网、电站用材料的评价以及新材料研究.
引用该论文: CHEN Yun-xiang,LIN De-yuan,HONG Yi-cheng,JIANG Zu-xuan,YANG Ju-xiao,SHAO Yan-qun. Corrosion Failure Analysis of Inner Al Layers of 35 kV Aluminium Cable Steel Reinforced (ACSR) Conductors[J]. Corrosion & Protection, 2015, 36(6): 594
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】周少玲,胡晓黎,岳增武.220 kV钢芯铝绞线断股事故化学分析[J].腐蚀与防护,2011,32(5):392-394.
【2】郑玉琪.架空输电线路微风振动[M].北京:水利电力出版社,1987.
【3】王闸,余雯,吴章勤,等.110 kV钢芯铝绞线失效原因分析[J].云南电力技术,2006,34(4):23-25.
【4】AZEVEDO C R F.Failure analysis of aluminum cable steel reinforced (ACSR) conductor of the transmission line crossing the parana river[J].Engineering Failure Analysis,2002,9(6):645-664.
【5】李旭东,穆志韬,刘治国,等.LY12CZ航空铝合金腐蚀疲劳断口研究[J].装备环境工程,2013,10(4):9-12.
【6】郑锦荣,张宝霖.输电导线腐蚀因素分析[J].国防杂志,2000,20(4):26-28.
【7】陈荐,黄志杰,李录平,等.架空导线微动磨损表而的微观分析[J].润滑与密封,2004,11:24-26.
【8】刘祖铭,曾凡阳,鲁礼菊,等.环境对LY12CZ铝合金典型螺接件疲劳性能的影响[J].中国腐蚀与防护学报,2004,24(5):267-271.
【9】张建堃,陈国宏,王家庆,等.干/湿NaCl盐雾条件下钢芯铝绞(ACSR)导线腐蚀层结构及腐蚀机理[J].腐蚀与防护,2010,31(8):581-586.
【10】王伟,朱成丽,吴洪亮,等.耐张线夹内钢芯铝绞线断裂原因及断口特征[J].腐蚀与防护,2014,35(3):297-301.
【2】郑玉琪.架空输电线路微风振动[M].北京:水利电力出版社,1987.
【3】王闸,余雯,吴章勤,等.110 kV钢芯铝绞线失效原因分析[J].云南电力技术,2006,34(4):23-25.
【4】AZEVEDO C R F.Failure analysis of aluminum cable steel reinforced (ACSR) conductor of the transmission line crossing the parana river[J].Engineering Failure Analysis,2002,9(6):645-664.
【5】李旭东,穆志韬,刘治国,等.LY12CZ航空铝合金腐蚀疲劳断口研究[J].装备环境工程,2013,10(4):9-12.
【6】郑锦荣,张宝霖.输电导线腐蚀因素分析[J].国防杂志,2000,20(4):26-28.
【7】陈荐,黄志杰,李录平,等.架空导线微动磨损表而的微观分析[J].润滑与密封,2004,11:24-26.
【8】刘祖铭,曾凡阳,鲁礼菊,等.环境对LY12CZ铝合金典型螺接件疲劳性能的影响[J].中国腐蚀与防护学报,2004,24(5):267-271.
【9】张建堃,陈国宏,王家庆,等.干/湿NaCl盐雾条件下钢芯铝绞(ACSR)导线腐蚀层结构及腐蚀机理[J].腐蚀与防护,2010,31(8):581-586.
【10】王伟,朱成丽,吴洪亮,等.耐张线夹内钢芯铝绞线断裂原因及断口特征[J].腐蚀与防护,2014,35(3):297-301.
相关信息