LABORATORY EVALUATION OF FERROMAGNETIC SCALE INHIBITION
摘 要
室内磁防垢实验的目的在于检测所选磁化器对现场水质的防垢效果.研究采用了西安石油大学磁防垢项目组设计的强磁防垢室内实验效果评价装置,该装置在材质、形状、传热过程、水流状态、加热温度等方面尽量模拟孤东采油厂垦东大站(KD521)掺水系统,在此实验流程基础上利用金相显微观察法优选磁化器进行室内实验效果评价,找出了最适合KD521掺水系统水质的磁化器类型.室内实验结果表明,磁化系统与空白系统相比,阻垢率为70%左右,而现场应用要好于此效果,建议现场采用强磁防垢装置.
Abstract
The effect of magnetic equipment for ferromagnetic antiscale on the water quality was studied using a home made apparatus of ferromagnetic antiscale,which simulated the material,shape,heat conducting process,heating temperature and water flow state of the water mixing system in KenDong station(KD521) of GuDong oil field.An optimal ferromagnetic syale inhibition device suitable to KD521 water mixing system was selected.The antiscale rate of ferromagnetic system was about 70% as compared with that of blank system.In oil field,the antiscaling effect was even better.
中图分类号 TQ085
所属栏目 应用技术
基金项目
收稿日期 2005/4/5
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: SUN Zhi-yu,PU Chun-sheng,XIE Li-hua. LABORATORY EVALUATION OF FERROMAGNETIC SCALE INHIBITION[J]. Corrosion & Protection, 2006, 27(1): 20~22
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】[苏]B.и.克拉辛著,毛钷凡,等译.磁化水[M].北京:计量出版社,1982.16-67.
【2】陈蓬西.浅谈水的磁场处理及前景[J].工业水处理,1984,4(5):34-35.
【3】陈昭威.磁场处理水的机理的探讨[J].物理,1992,21(2):109-112.
【4】中国石油化工总公司生产部、发展部.冷却水分析和实验方法[M].安庆:安庆石化信息中心,1993.402-413.
【2】陈蓬西.浅谈水的磁场处理及前景[J].工业水处理,1984,4(5):34-35.
【3】陈昭威.磁场处理水的机理的探讨[J].物理,1992,21(2):109-112.
【4】中国石油化工总公司生产部、发展部.冷却水分析和实验方法[M].安庆:安庆石化信息中心,1993.402-413.