MEASUREMENT AND COMMISSIONING OF ICCP SYSTEM FOR LARGE-SCALE STORAGE TANK′S OUTER BOTTOM
摘 要
本文介绍了大型储罐底板的基础特点及适用的阴极保护形式.另外,综合相关的国家标准和NACE标准及API标准,对大型储罐外底板的阴极保护系统的参数测量、系统调试和验收方法进行了比较和探讨,并结合工程实例进行了说明.
Abstract
The foundation and impressed current cathodic protection (ICCP) system of large-scale storage tanks was summarized.The optimal ICCP system for large-scale storage tanks is introduced.The measurement and system commissioning methods for large-scale tank’s ICCP system are also discussed after studying the National Standards,NACE and API standards.Some new ideas are presented based on the practice.
中图分类号 TG174.41
所属栏目 应用技术
基金项目
收稿日期 2006/4/14
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: SU Jun-hua,CHEN Hang,WANG Chen. MEASUREMENT AND COMMISSIONING OF ICCP SYSTEM FOR LARGE-SCALE STORAGE TANK′S OUTER BOTTOM[J]. Corrosion & Protection, 2006, 27(12): 632~636
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】Mohammed Ali.Titanium ribbon anode grid type cathodic protection system for above ground storage tank bottoms with double containment – a case study[A].Corrosion 99[C].Paper No.289,NACE,1987.
【2】王晨,顾望平.12.5×104m3储油罐底板阴极保护方案比选[J].石油化工设备技术,2003,24(3).
【3】过梦飞.混合金属氧化物(MMO)网状阳极系统的设计和安装[J].腐蚀与防护,2000,21(11):495-497.
【4】闫久红,丁乙,胡士信,等.柔性阳极在库鄯输油管道上的应用[J].油气储运,1999,18(4):33-38.
【5】SY 0007-1999,钢质管道及储罐腐蚀控制工程设计规范[S].
【6】SY/T 0023-1997,埋地钢质管道阴极保护参数测试方法[S].
【7】API RP 651,Cathodic protection of aboveground petroleum storage tanks[S].1991.
【8】NACE RP0285,Corrosion control of underground storage tank systems by cathodic protection[S].1995.
【9】NACE RP0193,External cathodic protection of on-grade metallic storage tank bottoms[S].1994.
【10】NACE TM0497,Measurement techniques related to criteria for cathodic protection on underground or submerged metallic piping systems[S].1997.
【2】王晨,顾望平.12.5×104m3储油罐底板阴极保护方案比选[J].石油化工设备技术,2003,24(3).
【3】过梦飞.混合金属氧化物(MMO)网状阳极系统的设计和安装[J].腐蚀与防护,2000,21(11):495-497.
【4】闫久红,丁乙,胡士信,等.柔性阳极在库鄯输油管道上的应用[J].油气储运,1999,18(4):33-38.
【5】SY 0007-1999,钢质管道及储罐腐蚀控制工程设计规范[S].
【6】SY/T 0023-1997,埋地钢质管道阴极保护参数测试方法[S].
【7】API RP 651,Cathodic protection of aboveground petroleum storage tanks[S].1991.