Failure Analysis of Water Pump Valve in Power Plant
摘 要
某发电厂给水泵阀门在使用中发生泄漏.通过解体检查和失效分析后认为该阀门由于填料中吸附了较多的腐蚀性元素和水分,腐蚀介质局部浓度升高,满足了腐蚀的介质条件,闸阀门杆表面产生了缝隙腐蚀,粗糙度变差,经多次开启和闭合后,闸阀门杆对碳纤维垫片的损害程度加重,其配合间隙相应变大,填料丧失了密封性,造成给水泵阀门泄漏.
Abstract
Leakage of a water pump valve in a power plant was found in use.Disaggregation checking and failure analyses showed that the leak of this pump valve could meet the condition of crevice corrosion when the stuffing filled with corrosive medium.Coarseness of valve surface became severe after corrosion,and the carbon fibre gasket was damaged after circles.Then the stuffing lost the function of airproof,and the pump valve began leaking when the gap between rod and stuffing increased.
中图分类号 TG172.2
所属栏目 失效分析
基金项目
收稿日期 2007/5/15
修改稿日期 2007/6/20
网络出版日期
作者单位点击查看
引用该论文: WANG Rong. Failure Analysis of Water Pump Valve in Power Plant[J]. Corrosion & Protection, 2008, 29(4): 223~225
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】任赞颂,张静江,陈质如,等.钢铁金相图谱[M].上海上海科学技术文献出版社,2003:868.
【2】王荣.不锈钢换热器板片泄露原因分析[J].理化检验-物理分册,2006,42(5):257.
【3】王荣,李玲.不锈钢链板开裂原因分析[J].机械工程材料,2007,31(1):59.
【4】小若正伦,著,袁宝林,等译.金属的腐蚀破坏与防蚀技术[M].北京:化学工业出版社,1988.
【5】桂立丰,吴民达,赵源,等.机械工程材料测试手册[M].腐蚀与摩擦学卷,辽宁:辽宁科学技术出版社,2002:214.
【2】王荣.不锈钢换热器板片泄露原因分析[J].理化检验-物理分册,2006,42(5):257.
【3】王荣,李玲.不锈钢链板开裂原因分析[J].机械工程材料,2007,31(1):59.
【4】小若正伦,著,袁宝林,等译.金属的腐蚀破坏与防蚀技术[M].北京:化学工业出版社,1988.
【5】桂立丰,吴民达,赵源,等.机械工程材料测试手册[M].腐蚀与摩擦学卷,辽宁:辽宁科学技术出版社,2002:214.