介绍了埋地管道防护层缺陷电位梯度检测技术.用盐溶液、蒸馏水和自来水的混合液模拟土壤介质,通过改变管道防护层缺陷大小,改变环境电阻率和保护电流,试验证明了电位梯度检测技术能够比较准确地检测出管道防腐层缺陷的位置,并得到了管道埋深和地表电位梯度的关系.
Abstract
The principle and method of the detection technique of DCVG is introduced.Through changing the size of defects,environment resistance rate,protective current,simulation tests proved that DCVG technique could detect the defect locations,and the relationship between the depth of underground pipeline and the earth surface voltage gradients could be obtained.