Effect of HEDP on Corrosion Behavior of 1Cr18Ni9Ti in HNO3 Cleaning System
摘 要
采用电化学测试、金相及电子扫描探针检测,研究羟基乙叉二膦酸(HEDP)对1Cr18Ni9Ti在硝酸清洗条件下(10% HNO3,50 ℃) 的腐蚀行为的影响.结果表明:添加HEDP后1Cr18Ni9Ti在HNO3体系中的耐点蚀性能进一步提高,且HNO3与HEDP的二次钝化有一定的协同作用,有利于 1Cr18Ni9Ti在HNO3体系中钝化膜破坏后的再修复.
Abstract
The effect of HEDP on corrosion behavior of 1Cr18Ni9Ti in HNO3 cleaning system (10% HNO3,50 ℃) was studied by electrochemical testing,metallographic and electronic scanning probe observation.The results showed that the pitting resistance of 1Cr18Ni9Ti was further improved by adding HEDP to HNO3 system.The synergistic effet between HNO3 and HEDP′s secondary passivation would promote the repair of passivation film of 1Cr18Ni9Ti damaged in HNO3 system.
中图分类号 TG174.4
所属栏目 试验研究
基金项目 中国工程物理院项目资助;四川省教育厅重点科研项目(No:08ZA084)资助
收稿日期 2009/3/2
修改稿日期 2009/4/2
网络出版日期
作者单位点击查看
备注龚敏,教授.
引用该论文: GONG Min,WEI Wei,ZHANG Peng,LIN Xiu-zhou,KANG Wu,ZHANG dong,ZHAO Chao-kang. Effect of HEDP on Corrosion Behavior of 1Cr18Ni9Ti in HNO3 Cleaning System[J]. Corrosion & Protection, 2010, 31(2): 115~117
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】李仲先.循环冷却水的水质稳定与处理[M].北京:冶金工业出版社.1987.
【2】周本省.循环冷却水系统中的结垢问题[J].化学清洗,1999,15(3):36-42.
【3】秦国治,李欣红.化学清洗实用技术[M].北京:中国石化出版社,1996.
【4】Pnggo M,Norman H.The effect of some organic phosphorus compounds on the corrosion behavior of iron in 6M HCl[J].Anti-Corrosion methods and materials,1998,45(6):413-418.
【5】郭稚弧.缓蚀剂及其应用[M].武汉:华中工学院出版社,1987:89-163.
【6】赵麦群,雷阿利.金属的腐蚀与防护[M].北京:国防工业出版社,2002.
【7】宋诗哲.腐蚀电化学研究方法[M].北京:化学工业出版社,1988.
【2】周本省.循环冷却水系统中的结垢问题[J].化学清洗,1999,15(3):36-42.
【3】秦国治,李欣红.化学清洗实用技术[M].北京:中国石化出版社,1996.
【4】Pnggo M,Norman H.The effect of some organic phosphorus compounds on the corrosion behavior of iron in 6M HCl[J].Anti-Corrosion methods and materials,1998,45(6):413-418.
【5】郭稚弧.缓蚀剂及其应用[M].武汉:华中工学院出版社,1987:89-163.
【6】赵麦群,雷阿利.金属的腐蚀与防护[M].北京:国防工业出版社,2002.
【7】宋诗哲.腐蚀电化学研究方法[M].北京:化学工业出版社,1988.
相关信息