Failure Analysis of Field Joint Coating(FJC) and Suggestion
摘 要
热收缩带补口技术在中国石油新建管线工程中已经得到了广泛应用.但是,在热收缩带应用现场的调研过程中发现了补口失效.本工作结合现场施工工艺、热收缩带材料及相关实验室检测标准等分析了补口失效的原因,对热熔胶粘剂的改性研究、现场施工工艺的优化及防腐蚀保温材料实验室检测标准和方法的完善提出了建议.
Abstract
The field joint coating(FJC) technology based on heat shrinkable sleeves(HSS) has been used widely in the new oil/gas pipeline projects of PetroChina.However,there was some joint coating failure occurring in installation field.Results of failure analyses in the present work show that it is urgent to improve the performance of key materials,to optimize the installation process and to perfect the current standards and specifications applied to laboratory tests to enhance the quality control of FJC projects.Some suggestions have leen put forward.
中图分类号 TE988.2
所属栏目 应用技术
基金项目
收稿日期 2009/12/14
修改稿日期 2010/1/18
网络出版日期
作者单位点击查看
备注赵吉诗,工程师.
引用该论文: ZHAO Ji-shi,HOU Yu,ZHAO Guo-xing,LIU Ling-li,DU Zhong-jie. Failure Analysis of Field Joint Coating(FJC) and Suggestion[J]. Corrosion & Protection, 2010, 31(10): 812~814
被引情况:
【1】廖煜炤,王杰,李建军,李晓峰,郑安升,付伟, "聚乙烯热收缩带补口施工工艺应用现状和发展趋势",腐蚀与防护 35, 602-606(2014)
【2】孙海明,刘立群,张海雷, "管道3LPE防腐蚀层补口失效原因及建议",腐蚀与防护 37, 60-63(2016)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差