Corrosion of Metal in Chlorine Dioxide Disinfection Solution
摘 要
采用静态失重法试验了常温下A3钢、铜、铝、不锈钢在50 mg/L、100 mg/L、200 mg/L和400 mg/L的二氧化氯溶液中的腐蚀情况.结果表明,在200 mg/L二氧化碳消毒体系下,铝为轻度腐蚀,铜为中度腐蚀:在400 mg/L二氧化氯消毒体系下,A3钢为重度腐蚀,不锈钢为轻度腐蚀.并分析了腐蚀的原因,为二氧化氯的广泛应用提供基础.
Abstract
The corrosion of A3 steel,copper,aluminum,stainless steel in 50 mg/L,100 mg/L,200 mg/L and 400 mg/L chlorine dioxide disinfection solution at room temperature was studied by the method of static weight-loss.The results showed that when the concentration of chlorine dioxide disinfection solution was 200 mg/L,the corrosion degree of aluminum was mild and that of copper was moderate;when the concentration of chlorine dioxide was 400 mg/L,the corrosion degree of A3 steel was severe and that of stainless steel was mild.The possible corrosion reason was analyzed.
中图分类号 TG172.6
所属栏目 应用技术
基金项目
收稿日期 2010/1/13
修改稿日期 2010/3/11
网络出版日期
作者单位点击查看
联系人作者康志娟(kzj0825@163.com)
备注康志娟,硕士研究生.
引用该论文: KANG Zhi-juan,WANG Kui-tao,ZHAO Hai-dong,WU Hai-xia,LU Nan,SUN Ya-wei,XING Shi-hui. Corrosion of Metal in Chlorine Dioxide Disinfection Solution[J]. Corrosion & Protection, 2010, 31(12): 984~985
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】董小峰,高红梅,张志成.两种消毒剂在内镜消毒机上对内镜模拟现场消毒效果观察[J].中国消毒学杂志,2005,22:286-287.
【2】马春梅,刘翠梅,袁慎坡.3种高效消毒剂对牙科器械腐蚀性研究[J].中华医院感染学杂志,2008,18(2):218-220.
【3】宋 鸿,奚旦立.二氧化氯的腐蚀性研究[J].中国纺织大学学报,1998,24(6):83-86.
【4】中华人民共和国卫生部.消毒技术规范2002年版[M].北京:中华人民共和卫生部,2002:124-126.
【2】马春梅,刘翠梅,袁慎坡.3种高效消毒剂对牙科器械腐蚀性研究[J].中华医院感染学杂志,2008,18(2):218-220.
【3】宋 鸿,奚旦立.二氧化氯的腐蚀性研究[J].中国纺织大学学报,1998,24(6):83-86.
【4】中华人民共和国卫生部.消毒技术规范2002年版[M].北京:中华人民共和卫生部,2002:124-126.
相关信息