Concave Analysis on Surface of Piercing Plug
摘 要
某热轧厂在进行穿孔操作过程中,一支顶头仅穿孔50次就发现其表面存在凹陷缺陷,将其与穿孔200次仍完好的顶头进行了理化检验及对比分析.结果表明:顶头氧化层出现游离块状铁素体,导致该区域组织松散、硬度降低,进而致使顶头出现凹陷缺陷而失效.
Abstract
During the process of punching in a hot rolling plant,concave defect was found on the surface of a piercing plug which was used for only 50 times.The piercing plug was compared with another intact one used for 200 times from the aspects of physical testing and chemical anslysis.The results show that the structure became loose and the hardness declined due to the granular ferrite existing in the oxidation layer,which led to the concave defect on the surface of the piercing plug.
中图分类号 TG115 DOI 10.11973/lhjy-wl201509019
所属栏目 质量控制与失效分析
基金项目
收稿日期 2014/10/17
修改稿日期
网络出版日期
作者单位点击查看
备注蔡煜(1984-),女,助理工程师.
引用该论文: CAI Yu,ZHENG Zhen,SHU Hao,CAI Mei-yan. Concave Analysis on Surface of Piercing Plug[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2015, 51(9): 675~677
蔡煜,郑臻,舒浩,蔡梅艳. 穿孔顶头的表面凹陷分析[J]. 理化检验-物理分册, 2015, 51(9): 675~677