Failure Analysis on Barb Bolt of a Condensing Tower
摘 要
通过宏观、化学成分、金相、断口与能谱分析等方法,对冷凝塔地脚螺栓的断裂进行了失效分析.结果表明:螺栓在服役2 a后就发生了断裂,主要是因为螺栓加工不良和钢中存在严重的偏析与夹杂物等冶金缺陷;在交变拉应力作用下,使得螺栓在螺纹沟处发生脆性疲劳断裂.
Abstract
The failure of the barb bolts in a condensing tower was studied by means of macrostructure,composition,metallography,fractography,EDS etc.The bolts was fractured after used for two years,resulting from bad working and serious metallurgical defects ,such as segregation and inclusion.The cracks are originated in the bottom of the screw thread due to fatigue fracture.
中图分类号 TG146.1
所属栏目
基金项目
收稿日期 2006/3/27
修改稿日期 2006/6/25
网络出版日期
作者单位点击查看
备注谷志刚(1954-),男,辽宁锦州人,教授级高级工程师,学士.
引用该论文: GU Zhi-gang,DU Hong-jian,LI Wei-hang,YOU Xiang-qun. Failure Analysis on Barb Bolt of a Condensing Tower[J]. Materials for mechancial engineering, 2007, 31(2): 59~61
谷志刚,杜宏建,李伟航,由向群. 冷凝塔地脚螺栓断裂失效分析[J]. 机械工程材料, 2007, 31(2): 59~61
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】束德林.工程材料力学性能[M].北京:机械工业出版社,2004.
【2】GB 1979-1980.结构钢低倍组织缺陷评级图[S].
【3】GB 10561-1989.钢中非金属夹杂物显微评定方法[S].
【4】范厚军.紧固件手册[M].南昌:江西科学技术出版社,2004.
【2】GB 1979-1980.结构钢低倍组织缺陷评级图[S].
【3】GB 10561-1989.钢中非金属夹杂物显微评定方法[S].
【4】范厚军.紧固件手册[M].南昌:江西科学技术出版社,2004.