Corrosion Resistance and Biocompatibility of A New Type of Medical Titanium Alloy Ti12.5Zr2.5Nb2.5Ta
摘 要
采用动电位扫描技术研究了新型医用Ti12.5Zr2.5Nb2.5Ta (TZNT)钛合金以及另外三种钛合金在林格氏溶液中的腐蚀行为,并对合金表面形成的钝化膜进行了分析,用皮下埋植试验评价了四种合金的生物相容性.结果表明:与另外三种合金相比,TZNT合金更易进入钝化状态;其钝化电位区间最宽,维钝电流较小,其表面的钝化膜更稳定,具有更优异的耐腐蚀性能;与Ti6Al4V和Ti6Al7Nb合金相比,TZNT和TA2合金植入白鼠体内4周和8周后无论是炎细胞密度还是植入物周围的纤维膜厚度均有所降低,具有良好的生物相容性.
Abstract
The potentiodynamic scanning polarization technique was performed to investigate the corrosion behavior of a new type of medical titanium alloy Ti12.5Zr2.5Nb2.5Ta (TZNT),and three titanlum alloys in Ringer′s solution.The passive film formed on the TZNT alloy surface was analyzed.The biocompatibility for the above four alloys was evaluated by means of the subcutaneous implant test.The results show that compared with the other three alloys the TZNT alloy entered into passive state more easily.Moreover,the passive film on the alloy surface was most stable owing to its more extensive passivation potential regions and lower passive current densities,therefore the alloy had outstanding corrosion resistance.The density of inflammation cells and the thickness of fibrous membrane around the implants decreased after in vivo implantation of the TZNT and TA2 alloy in mice for 4 and 8 weeles respectively,when compared with that in the Ti6Al4V and Ti6Al7Nb alloy.The TZNT alloy had good biocompatibility.
中图分类号 R318.08
所属栏目 材料性能及其应用
基金项目 上海市青年科技启明星计划资助项目(08QA14035)
收稿日期 2009/9/4
修改稿日期 2010/5/15
网络出版日期
作者单位点击查看
备注李军(1977-),男,内蒙古乌兰察布人,副教授,博士.
引用该论文: LI Jun,CHEN Du-juan,LI Zuo-chen. Corrosion Resistance and Biocompatibility of A New Type of Medical Titanium Alloy Ti12.5Zr2.5Nb2.5Ta[J]. Materials for mechancial engineering, 2010, 34(10): 55~58
李军,陈杜娟. 新型医用Ti12.5Zr2.5Nb2.5Ta钛合金的耐腐蚀性及生物相容性[J]. 机械工程材料, 2010, 34(10): 55~58
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】GORDINA D M,GLORIANTA T,NEMTOIB G,et al.Synthesis,structure and electrochemical behavior of a beta Ti-12Mo-5Ta alloy as new biomaterial[J].Mater Lett,2005,59:2959-2964.
【2】SAKAGUCHIA N,NIINOMIB M,AKAHONB T.Relationships between tensile deformation behavior and microstructure in Ti-Nb-Ta-Zr system alloys[J].Mater Sci Eng C,2005,25:363-369.
【3】KARAYAN A I,PARK S W,LEE K M.Corrosion behavior of Ti-Ta-Nb alloys in simulated physiological media[J].Mater Lett,2008,62:1843-1845.
【4】KHAN M A,WILLIAMS R L,WILLIAMS D F.The corrosion behaviour of Ti-6Al-4V,Ti6Al-7Nb and in protein solutions[J].Biomaterials,1999,20:631-637.
【5】WAPNER K L.Implications of metallic corrosion in total knee arthroplasty[J].Clin Orthop,1991,271:12-16.
【6】GEETHA M,SINGH A K,MURALEEHARAN K,et al.Effect of thermomechanical processing on microstructure of a Ti-13Nb-13Zr alloy[J].J Alloys Compd,2001,329:264-271.
【7】GEETHA M U,KAMACHI M,GOGIA A K,et al.Influence of microstructure and alloying elements on corrosion behavior of Ti-13Nb-13Zr alloy[J].Corros Sci,2004,46:877-892.
【8】NILSON T C,OLIVEIRA G,ALEIXO R,et al.Development of Ti–Mo alloys for biomedical applications: Microstructure and electrochemical characterization[J].Mater Sci Eng A,2007,452/453:727-731.
【9】STEINEMANN S G,PERREN S M.Titanium alloys as metallic biomaterials[C]//Lütjering G,Zwicker U,Bunk W.Proceedings of the 5th International Conference on Titanium.Münich: FRG,1985:1327-1334.
【10】李军,周廉,李佐臣,等.新型医用钛合金Ti-12.5Zr-2.5Nb-25Ta的研究[J].稀有金属材料与工程,2003,32(5):398-400.
【11】郭海霞,梁成浩,穆琦.TiNi及Co合金生物医用材料的腐蚀行为及血液相容性[J].中国有色金属学报,2001,11(增刊2):272-276.
【12】HELSEN J A,BREME J.Metals as biomaterials[M].New York: Wiley,1998.
【2】SAKAGUCHIA N,NIINOMIB M,AKAHONB T.Relationships between tensile deformation behavior and microstructure in Ti-Nb-Ta-Zr system alloys[J].Mater Sci Eng C,2005,25:363-369.
【3】KARAYAN A I,PARK S W,LEE K M.Corrosion behavior of Ti-Ta-Nb alloys in simulated physiological media[J].Mater Lett,2008,62:1843-1845.
【4】KHAN M A,WILLIAMS R L,WILLIAMS D F.The corrosion behaviour of Ti-6Al-4V,Ti6Al-7Nb and in protein solutions[J].Biomaterials,1999,20:631-637.
【5】WAPNER K L.Implications of metallic corrosion in total knee arthroplasty[J].Clin Orthop,1991,271:12-16.
【6】GEETHA M,SINGH A K,MURALEEHARAN K,et al.Effect of thermomechanical processing on microstructure of a Ti-13Nb-13Zr alloy[J].J Alloys Compd,2001,329:264-271.
【7】GEETHA M U,KAMACHI M,GOGIA A K,et al.Influence of microstructure and alloying elements on corrosion behavior of Ti-13Nb-13Zr alloy[J].Corros Sci,2004,46:877-892.
【8】NILSON T C,OLIVEIRA G,ALEIXO R,et al.Development of Ti–Mo alloys for biomedical applications: Microstructure and electrochemical characterization[J].Mater Sci Eng A,2007,452/453:727-731.
【9】STEINEMANN S G,PERREN S M.Titanium alloys as metallic biomaterials[C]//Lütjering G,Zwicker U,Bunk W.Proceedings of the 5th International Conference on Titanium.Münich: FRG,1985:1327-1334.
【10】李军,周廉,李佐臣,等.新型医用钛合金Ti-12.5Zr-2.5Nb-25Ta的研究[J].稀有金属材料与工程,2003,32(5):398-400.
【11】郭海霞,梁成浩,穆琦.TiNi及Co合金生物医用材料的腐蚀行为及血液相容性[J].中国有色金属学报,2001,11(增刊2):272-276.
【12】HELSEN J A,BREME J.Metals as biomaterials[M].New York: Wiley,1998.
相关信息