A New Method of Phase Measuring based on Hilbert and its Comparison with Digital Correlation Method
摘 要
介绍了希尔伯特(Hilbert)变换测量相位差和数字相关法测量相位差的原理,进行了比较研究和试验分析,讨论了各自使用效果、优缺点及其适用的场合。结果表明,在动态检测方面,利用Hilbert变换法更能对两路同频信号的相位差进行有效的检测,是今后的研究方向。
Abstract
The phase difference measuring principles of using Hilbert transform and digital correlation method are introduced, and the comparative research and experimental analysis are carried out based on their principles. Moreover, their respective application field and effectiveness, advantages and disadvantages are discussed. The results show utilizing Hilbert transform to measure the phase difference of two signals with the same frequency is more effective in dynamic testing, and is a research direction in the future.
中图分类号 TG115.28 TP391
所属栏目 科研成果与学术交流
基金项目
收稿日期 2005/1/11
修改稿日期
网络出版日期
作者单位点击查看
备注周继惠(1978~),女,讲师,从事测控技术的教学工作。
引用该论文: ZHOU Ji-hui,CAO Qing-song,SONG Jing-wei. A New Method of Phase Measuring based on Hilbert and its Comparison with Digital Correlation Method[J]. Nondestructive Testing, 2006, 28(7): 341~343
周继惠,曹青松,宋京伟. 基于Hilbert变换的相位测量法与数字相关测相法的比较[J]. 无损检测, 2006, 28(7): 341~343
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】任冠众,宁永兰.相位测量技术[J].电测与仪表,1999,(9):41-45.
【2】张毅刚,付 平,等.采用数字相关法测量相位差[J].计量学报,2000,21(3):216-221.
【3】岳瑞华,许化龙.基于数据采集板的相位测量新方法[J].计量技术,2001,(11):8-10.
【4】任吉林.电磁检测[M].北京:国防工业出版社,1999.
【2】张毅刚,付 平,等.采用数字相关法测量相位差[J].计量学报,2000,21(3):216-221.
【3】岳瑞华,许化龙.基于数据采集板的相位测量新方法[J].计量技术,2001,(11):8-10.
【4】任吉林.电磁检测[M].北京:国防工业出版社,1999.
相关信息