Helium Mass Spectrometer Leak Testing for the Flange
摘 要
改进并设计加工了法兰检漏专用吸枪和喷枪。研究和提出了充压真空法与氦罩法对法兰整体检漏的方法,利用法兰多道密封结构形成的环状空腔作为检漏真空室,进一步提高了法兰检漏的灵敏度与可靠性。
Abstract
The special sniffing probe and spray probe for leak testing of flange were designed and made. The inside-out testing and hood testing, two overall leak detection methods, were made research on and established. In these methods, the cavity which was ringed by multi-layer tight structures in the flange was used as the vacuum cave in leak detecting. By these means, the sensitivity and reliability of the leak detection for the flange were further improved.
中图分类号 TG115.28
所属栏目 试验研究
基金项目
收稿日期 2006/9/28
修改稿日期
网络出版日期
作者单位点击查看
备注胡茂中(1969-),男,硕士,高级工程师。
引用该论文: HU Mao-zhong,LIAO Xu-dong,FENG Xiao,CHEN Tao. Helium Mass Spectrometer Leak Testing for the Flange[J]. Nondestructive Testing, 2007, 29(5): 272~274
胡茂中,廖旭东,冯 晓,陈 涛. 法兰氦质谱检漏技术[J]. 无损检测, 2007, 29(5): 272~274
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】中川洋(日).防止泄漏的理论和实际应用[M].北京:化学工业出版社,1983.
【2】范垂祯.再议质谱检漏技术中的喷吹法和吸入法[J].真空,1998,(1):27-31.
【3】达道安.真空设计手册[M].第3版,北京:国防工业出版社,2004.
【4】吴孝俭,闫荣鑫.泄漏检测[M].北京:机械工业出版社,2004.
【2】范垂祯.再议质谱检漏技术中的喷吹法和吸入法[J].真空,1998,(1):27-31.
【3】达道安.真空设计手册[M].第3版,北京:国防工业出版社,2004.
【4】吴孝俭,闫荣鑫.泄漏检测[M].北京:机械工业出版社,2004.
相关信息