搜索热:失效分析 陶瓷
扫一扫 加微信
首页 > 期刊论文 > 论文摘要
一个值得重视的磁粉探伤机故障
          
Solution to a Failure of Magnetic Particle Testing Machine

沈科  
摘    要
CJW-3000型专用磁粉探伤机出现了左右工位探伤灵敏度不一致的情况。经检查是由于一侧导电回路中的螺丝钢板间被渗入的磁悬液氧化,使电阻加大所致。据此提出了仔细保养设备、仔细观察磁化规范、设置磁化时间检测报警电路和放置灵敏度检测装置的四种解决方法,以提高探伤的可靠性。
标    签 磁粉探伤机   综合灵敏度   磁化电流   Magnetic particle testing machine   General sensitivity   Magnetizing current  
 
Abstract
There was a sensitivity inconsistence phenomenon occurring on the right and left working position of magnetic particle testing machine CJW-3000. Following a careful checking, it was found that the inconsistence was caused by the screw steel plate oxide due to the suspension on the side of the conductive circuit, thus the corresponding resistance was increased. In order to improve the sensitivity and reliability, four resolution methods were put forward such as maintaining the equipment carefully, observing the magnetizing specification carefully, setting the alarm circuit of magnetizing time and setting sensitivity detection gauge.

中图分类号 TG115.28

 
  中国光学期刊网论文下载说明


所属栏目 实践经验

基金项目

收稿日期 2008/8/25

修改稿日期

网络出版日期

作者单位点击查看

备注沈科 (1979-),男,学士,工程师,负责机车车辆零部件的无损检测工作。

引用该论文: SHEN Ke. Solution to a Failure of Magnetic Particle Testing Machine[J]. Nondestructive Testing, 2009, 31(5): 400~401
沈科. 一个值得重视的磁粉探伤机故障[J]. 无损检测, 2009, 31(5): 400~401


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】李家伟,陈积懋.无损检测手册[M].北京:机械工业出版社,2004.
 
相关信息
   标题 相关频次
 磁粉检测中曲轴的退磁
 1
 基于梯形波磁化电流的便携式磁粉机能耗优化方案
 1
 双工位磁粉探伤机的研制
 1