The Technology of Measuring the Thickness of a Certain Spot of the Tube Under High Temperature
摘 要
管道高温定点测厚过程中存在测量数据偏大以及耦合剂选用不当引起的无法读数的问题。通过高温定点测厚试验研究, 将试验数据以温度与该温度下测厚所调整后的声速进行线性回归, 得出高温测厚的温度-声速线性方程。该方程用于管道高温定点测厚, 测量数据准确, 方法简便, 有效解决了测量数据偏大的问题。此外, 通过试验, 研究了高温耦合剂的性能, 筛选出高温状态下性能稳定的高温耦合剂。
Abstract
The problem of big data difference and the incapability of reading data caused by using inappropriate couplant existed during the process of measuring the thickness at the certain spot at high temperatures. Linear equation of sonic speed under high temperature in different materials was derived from linear regressive analysis on the experimental data of sonic speed both under certain temperature and the temperature below. The equation was applied to measure the thickness of a certain place on the tube under high temperature circumstances accurately and conveniently which could solve the problem of coincident large data effectively. Otherwise, through the research on the performance of different couplants, the appropriate couplants which were able to effectively couple under high temperature were screened.
中图分类号 TG115.28
所属栏目 试验研究
基金项目
收稿日期 2008/7/7
修改稿日期
网络出版日期
作者单位点击查看
备注崔轲龙(1981-), 男, 助理工程师, 学士, 主要从事腐蚀与防护研究工作。
引用该论文: CUI Ke-Long,LEI Jun-Liang,KONG Zhao-Hui,HUANG Xin-Quan,YUE Li-Xin. The Technology of Measuring the Thickness of a Certain Spot of the Tube Under High Temperature[J]. Nondestructive Testing, 2009, 31(6): 478~480
崔轲龙,雷俊良,孔朝辉,黄新泉,越立新. 管道高温定点测厚技术[J]. 无损检测, 2009, 31(6): 478~480
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】任有才.炼油装置主要设备及管道定点测厚研究及数据处理[J].石油化工腐蚀与防护, 2000, 17(2): 47.
【2】袁军国.腐蚀监测技术在镇海炼化公司的应用[J].石油化工腐蚀与防护, 2000, 19(6): 49-53.
【2】袁军国.腐蚀监测技术在镇海炼化公司的应用[J].石油化工腐蚀与防护, 2000, 19(6): 49-53.
相关信息