The Ultrasonic Guided Wave Testing to Heat Exchanger Pipes
摘 要
针对常规涡流检测技术不能实现全面快速检测在役换热器管的现状, 提出了换热器管超声导波检测技术, 并根据换热器管特点设计了专用的导波探头。在实际检测中将导波检测结果同涡流检测结果进行对比, 验证了该种方法可以实现快速、有效的全面检测电站常用换热器管。
Abstract
For conventional eddy current test cant examine heat exchanger pipes roundly and fleetly, a new method of ultrasonic guided wave detection technology was put forward. Special guided wave probe was designed according to characteristics of heat exchanger pipes. Comparaison results of the two technologies used in practical test showed their good confirmation. At the same time, special advantages of guided wave detection technology were shown.
中图分类号 TG115.28
所属栏目 试验研究
基金项目
收稿日期 2008/9/29
修改稿日期
网络出版日期
作者单位点击查看
备注牛晓光(1964-), 男, 高级工程师, 主要从事无损检测工作。
引用该论文: NIU Xiao-Guang,LIU Chang-Fu,ZHANG Yan-Xing,LI Zhong-Wei. The Ultrasonic Guided Wave Testing to Heat Exchanger Pipes[J]. Nondestructive Testing, 2009, 31(9): 685~688
牛晓光,刘长福,张彦新,李中伟. 换热器管超声导波检测[J]. 无损检测, 2009, 31(9): 685~688