New Operation Method of Vickers Hardness Indentation Test of Straight Line Arrangement on Fillet Weld
摘 要
根据设计和标准的要求,在角焊缝中心位置45°角处均匀测量维氏硬度,必须保证硬度压痕间隔为1 mm,角焊缝、热影响区和母材等部位的维氏硬度压痕呈直线行排列。笔者选用了HV-120型维氏硬度计,载荷98 N。为了达到标准要求,在硬度计工作平台上放置两块方型磁铁,以固定试样上、下不可移动,用游标卡尺的精度来保证压痕的间隔为1 mm,用45°角的三角板来确保角焊缝的中心线为45°。用这种方法进行维氏硬度试验,操作简单,压痕成为直线行排列均匀,测试结果准确可靠,满足了设计和标准的要求。
Abstract
According to requirements of design and test standard, when Vickers hardness on 45° center position of fillet weld was measured uniformly, indentation distance must be assured of 1 mm, Vickers hardness indentation of fillet weld, heat-affected zone, base metal and so on should be arranged in line. Vickers hardness tester whose type was HV-120 with 98 N of loading was used in experiment. In order to meet standard requirements, two square magnets were placed on job platform of hardness tester to fix the specimen which was not allowed to move up and down, indentation distance was rigidly defined of 1 mm by accuracy of vernier, centre line of fillet weld was determined of 45° by triangle plate with 45°. The operating method was simple, indentation of straight line arrangement was equation, testing results were accurate and reliable, and it was satisfied for the requirement of design and test standard.
中图分类号 TG115.5+1
所属栏目 试验技术与方法
基金项目
收稿日期 2009/12/3
修改稿日期
网络出版日期
作者单位点击查看
备注马俊华(1953-),男,高级技师。
引用该论文: MA Jun-hua. New Operation Method of Vickers Hardness Indentation Test of Straight Line Arrangement on Fillet Weld[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2010, 46(7): 441~442
马俊华. 角焊缝维氏硬度压痕直线行排列试验的新操作方法[J]. 理化检验-物理分册, 2010, 46(7): 441~442
被引情况:
【1】马俊华, "凹槽形补焊缝维氏硬度的梯度试验",理化检验-物理分册 48, 165-167(2012)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】弗里德曼Я Б.金属机械性能[M]. 束德林,译.北京: 机械工业出版社,1982.
【2】RCC-M 2000 法国压水堆核岛机械设备设计建造规则 S篇 附录SI 力学性能试验(SI500硬度测定)[S].
【3】李久林.金属硬度试验方法国家标准实施指南[M]. 北京:中国标准出版社,2004.
【2】RCC-M 2000 法国压水堆核岛机械设备设计建造规则 S篇 附录SI 力学性能试验(SI500硬度测定)[S].
【3】李久林.金属硬度试验方法国家标准实施指南[M]. 北京:中国标准出版社,2004.
相关信息