Analysis of Vibratory Stress Relief and Residual Stress on Trunnion Steel Girder
摘 要
为消除刘家道口弧形闸门支铰钢梁焊接后的残余应力,通过有限元分析,确定了采用振动时效工艺,并对振动时效的效果进行了分析。结果表明:振动时效方案可有效消除钢梁的残余应力,为同类工程消除残余应力提供了范例和经验。
Abstract
According to theory analysis,the vibratory stress relief (VSR) technique was used on trunnion steel girder of pivoted gate in Liujiadaokou water complex project,which helps eliminate the residual stress. The effect of VSR was analyzed. The results showed that the residual stress on girder was eliminated effectively by VSR technique which validated by finite element method. It provided important experience for other projects.
中图分类号 TG115.9
所属栏目 试验技术与方法
基金项目
收稿日期 2008/1/14
修改稿日期
网络出版日期
作者单位点击查看
备注胡木生(1978-),男,工程师。
引用该论文: HU Mu-sheng,MEI Yan,HAN Zhi-gang,NI Guo-sheng. Analysis of Vibratory Stress Relief and Residual Stress on Trunnion Steel Girder[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2009, 45(3): 148~151
胡木生,梅 燕,韩志刚,倪国胜. 支铰钢梁的振动时效与残余应力分析[J]. 理化检验-物理分册, 2009, 45(3): 148~151
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】王勖成. 有限单元法[M]. 北京:清华大学出版社,2007.
【2】CB/T 3395-1992 残余应力测试方法 钻孔应变释放法[S].
【2】CB/T 3395-1992 残余应力测试方法 钻孔应变释放法[S].